4
safety valve (
5
) counter-clockwise simultaneously. This opens up the valve, letting the gas to the
nozzle of the burner (
6
), and turns the ignition switch to
on (7)
at the same time. The electrical
current is automatically supplied from the battery to spark plug generator (
8
), and then to the pin
heads (
9
), causing the ignition (
10
). The burner is ignited and bursts into flame (
11
).
3.
COMPONENTS SPECIFICATION
- Glass 3B = Float glass 8.0x460x760 mm
- Bottom plate forming=Zinc coat
- Knob= heat + flame resistance
- Washer= fiber
- Hose end=Brass (size1/2A)
- Rubber grommet (glass model)
= Silicone heat resistance
- Spark generator 4p=1.5Vdc+90C+electrode10KV
Summary of Contents for EGT 9425K
Page 1: ...SERVICE MANUAL ...
Page 9: ...8 6 WIRING DIAGRAM ...
Page 12: ...11 8 SPARE PARTS ...
Page 15: ...14 ...