By-pass diameters
Burner
Ø By-pass in
1/100 mm
Burner
Ø By-pass in
1/100 mm
Auxiliary
28
Triple Crown
56
Semi-rapid
32
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW
inj. 1/100 mm
Auxiliary
1.0
70
Semi-rapid
1.9
96
Triple Crown
3.8
146
Gas burners for LPG (Butane / Propane) G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
inj. 1/100
mm
G30
28-30
mbar
G31
37 mbar
g/h
g/h
Auxiliary
1.0
50
73
71
Semi-rapid
1.9
71
138
136
Triple Crown
3.8
98
276
271