background image

5

Unpacking

Check that the cooker hood has no damages. Trans-
portation damages should immediately be reported
to the one responsible for the transport Damages,
faults and eventually missing details should immedi-
ately be reported to the seller.
Take care of the packing material so that small
children cannot play with it.

Placement

The hood is to be mounted on the wall or under a
wall cupboard.
When installed, the hood must be not less than
60 cm. above electric burners or 70 cm. above
gas or mixed-fuel burners. (Fig. 4).

Electrical connection

The hood has a power cord with moulded plug with
earth connection to be connected to a wall outlet of
230 V.
The power cord length is 1 m.

Mounting of hood on wall

l

Fix the drilling template to the wall (Fig. 5).

l

Make 3 Ø 8 mm holes in the wall.  2 at points H,
1 as desired at points I.

l

Insert the three Ø  8 mm expansion plugs into the
wall.

l

Insert 2 5x45 screws at points H but do not
tighten them completely.

l

Open the grid.

l

Fit the hood into holes H, tighten the 2 screws.

l

From inside the hood, insert the third 5x45 screw
into hole I (Fig. 6).

Installation

Special accessories

Active carbon filter

When the hood is used in recirculation mode an
active carbon filter should be used.
Order by the retailer
PNC 942 120 180

Fig. 4

Fig. 5

Min

70 cm

Min

60 cm

I

H

H

I

H

H

I

I

H

H

I

I

CLOSED

OPEN

CLOSED

OPEN

Fig. 6

Summary of Contents for EFT 625

Page 1: ...User Manual EFT 925 EFT 625 UK ...

Page 2: ...trical connection 5 Mounting of hood on wall 5 Mounting under cupboard 6 Exhausting mode 6 Recirculation mode with carbon filter 6 Using the hood 6 Speed regulation 6 Work light 7 Correct ventilation 7 Important to know 7 Maintenance 7 Grease filter 7 Carbon filter 7 Attention 8 Cleaning 8 Changing the lighting elements 8 If the hood does not function 8 Service and spare parts 8 Technical data 9 ...

Page 3: ...es l The hood cannot be connected to flues of other appliances that run on energy sources other than electricity Please keep to the provisions of official direc tives regarding the question of fumes discharge l When the hood is used at the same time of other appliances that run on energy sources other than electricity provision must be made for an adequate supply of air l When installed the hood m...

Page 4: ... F from the top hole Connect the hood to the smoke exhaust hose by using the connecting ring G with no return valve bayonet coupling Insert plug H in the unused exhaust hole bayonet coupling Plug H is for closing the unused hole Attention In the horizontal runs the duct must be slightly slanted about 10 and directed upwards to vent the air easily from the room to the outside The hood cannot be con...

Page 5: ...oulded plug with earth connection to be connected to a wall outlet of 230 V The power cord length is 1 m Mounting of hood on wall l Fix the drilling template to the wall Fig 5 l Make 3 Ø 8 mm holes in the wall 2 at points H 1 as desired at points I l Insert the three Ø 8 mm expansion plugs into the wall l Insert 2 5x45 screws at points H but do not tighten them completely l Open the grid l Fit the...

Page 6: ...on filter The air outlets D Fig 2 must be shut l Open the suction grid Fig 12 l Check that the selection lever for evacuation recycle is in the position F recycle Fig 8 l Check if carbon filter is already mounted and if not fit carbon filter first rearwards on the proper seats l Then fix frontwards the carbon filter using hooks C Fig 9 Using the hood Speed regulation The hood has a three speed mot...

Page 7: ...Grease filter This serves to hold the grease particles in suspen sion Model EFT 625 is supplied with two grease filters model EFT 925 is supplied with one grease filter The metal filter should be washed every month with warm soapy water or if possible in the dishwasher 60 C Remove the filter l Open the latch and rotate the grid downwards Fig 12 l To remove pull forward from the right hand side and...

Page 8: ...you make contact to service Check that the power plug is connected to the wall power outlet and that no fuse is blown Do not do any operations that can cause hazard or damage to the product If the problem remains contact your dealer or an approved service company Remember to save the purchase recite and the Warranty card only used in some countries Service and spare parts Service and spare parts y...

Page 9: ...0 W E 14 2 x 40 W E 14 Grease filter 2 pc 1 pc Mains Voltage 230 V 230 V Electric safety class Class 2 Class 2 Power rating total 330 W 330 W 599 119 130 85 370 98 320 345 27 37 195 65 495 899 119 130 85 370 98 320 345 27 37 195 65 495 EFT 625 EFT 925 ...

Page 10: ......

Page 11: ......

Page 12: ...LI1PJA Ed 03 01 ...

Reviews: