Installation between two cabinets

The locking screws must be in place (x 2).

If this is not the case, the hood could drop.

If the hood is to be installed in such a way that the

top edge of the front panel is aligned with the base

of the cabinet (see figure 1), follow the instructions

provided for "Installing the hood in a cabinet" with

16 mm walls, points 3-8.

If the hood is to be installed at a height above that

of the cabinet base:

1.

Use the installation template to trace two

vertical lines on either side (see figure 2).

2.

Measure the height at which the hood must be

installed.

3.

Install the suspension bars (see figure 3).

The drawing illustrates the left-hand side. The

right-hand side is the exact opposite.

4.

Raise the hood and insert the hooks in the

special slots.

5.

Push the hood against the wall. Check that all

the hooks are correctly inserted in the slots.

6.

Install the locking screw (see "Installing the

hood in a cabinet", figure 4).

Electrical connection

The electricity socket must be situated above the

hood, inside a wall cabinet. The hood is supplied

with an electrical power supply cable fitted with a

moulded plug with an earthing pin, suitable for a

230 V wall socket.

Depth adjustment

Once the hood has been installed, adjust it so that

it is in line with the wall.

1.

Remove the filter as illustrated in the chapter

entitled "Care and cleaning".

2.

Unscrew the screws (see figure).

3.

Push the adjustment arms against the wall.

4.

Tighten the screws.

5.

Reposition the grease filter.

1.

2.

3.

1

2

Summary of Contents for EFP 6446

Page 1: ...brauchsanweisung Installatie en gebruiksaanwijzing Notice d utilisation et d installation EFP 6446 EFP 6456 NL D Operating and Installation Instructions Instrucciones de montaje y manejo Manual de Instruções UK F E P ...

Page 2: ...ead the chapter entitled Care and cleaning in this manual Scrapping When scrapping the hood take all the necessary steps set forth by the law to prevent all future accidents Unplug the plug on the power supply cable from the wall socket and cut the cable near the appliance air inlet Contact your local authorities for details on scrapping your hood How to read this user manual The symbols below wil...

Page 3: ...1 60 cm Intake grid Intake grid for re circulation PNC 391 433 101 Operation The hood can operate in two ways By venting the air outside using the flue kit and flue duct By re circulating the air using a charcoal filter filter sold separately The hood must not be connected to a flue duct used for the flue gases originating from appliances that do not run on electricity Use the charcoal filter The ...

Page 4: ... is pulled out To set the intensive speed then push the push button A see figure the intensive speed lasts for 5 minutes For best results low speeds are recommended under normal operating conditions and higher speed settings when the concentration of fumes and steam are highest Turn the hood on a few minutes before you begin cooking in order to create a partial vacuum in the kitchen Once you have ...

Page 5: ...ower the fan motor load which improves ventilation performance Lowering the front visor Note Do NOT overload the pull out glass visor by resting on it or subjecting it to abnormal loads The front visor can be lowered to facilitate cleaning operations 1 Push the front visor upwards until it rests against the rear edge see figure 2 Lower the visor until it reaches the front edge see figure 3 After c...

Page 6: ...operly and check the fuses on the fuse box of your home Do not attempt anthing that may involve a risk or damage the appliance If the problem persists contact your retailer or our after sales service centre Repairs and spare parts Please contact your retailer for all repair work and spare parts Before calling our after sales service centre note the appliance serial number and the model name This i...

Page 7: ...96 mm 596 mm Depth 315 mm 320 mm Lighting max 2 x 20 W max 2 x 20 W Grease filter 1 1 Electrical connection 230 V 230 V Electric Safety class I I Maximum absorbed power 310 W 310 W 300 345 17 460 430 8 596 140 7 0 95 120 20 185 EFP 6456 300 345 17 460 430 13 15 180 596 140 7 0 95 120 EFP 6446 ...

Page 8: ... Trace a line using the installation template to guide you see figure 1 Saw along this line and cut a groove at the base of the top part of the cabinet 2 Measure the thickness of the cabinet walls see figure 2 The most common wall thicknesses are 16 and 19 mm If the thickness is any different choose the closest thickness 3 Install the suspension bars see figure 2 on the installation template The d...

Page 9: ...s the left hand side The right hand side is the exact opposite 4 Raise the hood and insert the hooks in the special slots 5 Push the hood against the wall Check that all the hooks are correctly inserted in the slots 6 Install the locking screw see Installing the hood in a cabinet figure 4 Electrical connection The electricity socket must be situated above the hood inside a wall cabinet The hood is...

Page 10: ...e The LONG LIFE charcoal filter special accessory for this hood is installed instead of the grease filter The LONG LIFE charcoal filter is both a grease filter as well as a charcoal filter designed to minimise unpleasant cooking odours An opening must be made underneath or on the front of the cabinet min 100 cm where the hood is installed so that the filtered air can circulate freely and return to...

Page 11: ...er of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world Electrolux 2003 ...

Reviews: