10 electrolux
Installation
EN
Hood body installation
•
Before attaching the hood body,
tighten the two screws
Vr
located on
the hood body mounting points.
• Hook the hood body onto the screws
12a
.
• Fully tighten support screws
12a
.
• Adjust screws
Vr
to level the hood
body
Connection in Ducting Version
When installing the ducting version,
connect the hood to the chimney using
either a
fl
exible or rigid pipe ø 150 or
120 mm, the choice of which is left to
the installer.
• To install a ø 120 mm air exhaust con-
nection, insert the reducer
fl
ange
9
on
the hood body outlet.
• Fix the pipe in position using suf
fi
cient
pipe clamps (not supplied).
• Remove charcoal
fi
lters, if present.
Connection in Recycling Version
• Fix the
fl
ange
10
to the lower opening
of the connection
15
.
• Connect the hood air outlet to the
fl
ange in the lower part of the junction
using a rigid or
fl
exible ø 150 tube (by
installer’s choice).
• Ensure that the charcoal
fi
lters have
been
fi
tted.
Electrical Connection
• Connect the hood to the mains
through a two-pole switch having a
contact gap of at least 3 mm.
• Remove the grease
fi
lters (see para-
graph Maintenance) being sure that
the connector of the feeding cable is
correctly inserted in the socket placed
on the side of the fan.
12a
Vr
9
ø 120
ø 150