Activated charcoal filter (Recirculation version) 

•  The filter is not washable and cannot be regenerated. It must be replaced when led S1 

flashes or at least every 4 months. The alarm signal will only light up when the extractor 
motor is switched on. 

Alarm signal activation 
•  In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or 

at a later date. Turn the Lights and the suction Motor off. 

•  Disconnect the Hood using the Main switch or the double-pole switch on the mains power 

supply. 

•  Restore the connection by pressing and holding 

T1

•  Release the button.  All five LEDs are turned on 
• 

Within 3 seconds

 press T1 until LEDs  

T1

 and 

T4

 flash in confirmation: 

  LED flashes twice - Activated charcoal filter saturation alarm ENABLED 
  LED flashes once - Activated charcoal filter saturation alarm DISABLED 

 

Replacing the activated charcoal filter 

Alarm signal reset 

•  Switch off the lights and extractor motor. 
• Press button 

T3

 for at least 3 seconds, until the leds start to 

flash. 

Replacing the Filter

 

•  Remove the metal grease filters 
•  Remove the saturated activated carbon filter by releasing the 

fixing hooks 

•  Fit the new filter by hooking it into its seating 
•  Replace the metal grease filters. 

 

 

Lighting 

LIGHT REPLACEMENT 

20 W halogen light. 

•  Remove the 2 screws fixing the Lighting support, and pull it 

out of from the Hood. 

•  Extract the lamp from the Support. 
•  Replace with another of the same type, making sure that the 

two pins are properly inserted in the lamp holder socket holes. 

•  Replace the Support, fixing it in place with the two screws re-

moved as above.  

 

 

Summary of Contents for EFC 9541

Page 1: ...EFC 9541 Instructions Manual Bedienungsanleitung ...

Page 2: ...EN 2 2 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 4 CHARACTERISTICS 5 INSTALLATION 7 USE 10 MAINTENANCE 11 ...

Page 3: ...DE 3 3 Bedienungsanleitung INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 13 CHARAKTERISTIKEN 14 MONTAGE 16 BEDIENUNG 19 WARTUNG 20 ...

Page 4: ...gree of aeration must be guaranteed in the room in order to prevent the backflow of ex haust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Never leave h...

Page 5: ...EN 5 5 CHARACTERISTICS Dimensions 650 min ...

Page 6: ...wer frame 9 1 Reducer Flange ø 150 120 mm 10 1 Flange ø 150 15 1 Air Outlet Connection 24 1 Junction box 25 2 Pipe clamps Ref Q ty Installation Components 11 4 Wall Plugs ø 10 12c 6 Screws 2 9 x 6 5 12e 2 Screws 2 9 x 9 5 12f 4 Screws M6 x 10 12g 4 Screws M6 x 80 12h 4 Screws 5 2 x 70 21 1 Drilling template 22 4 6 4 mm int dia washers 23 4 M6 nuts Q ty Documentation 1 Instruction Manual 12c 7 1a 7...

Page 7: ...ings with wall thickness of 20 mm drill ø 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill ø 7 mm For the power supply cable feed drill ø 10 mm For the air outlet Ducted Version drill according to the diameter of the external air ex haust duct connection Insert two screws of the following type crossing them and ...

Page 8: ...he frame by turning it Make sure that the screws do not come out of their seats in the slotted holes The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device On completion check that the base is stable even if the frame is subjected to bending In all cases where the ceiling is not strong enough at the sus pen...

Page 9: ...emove the grease filters from the hood body Remove any activated charcoal filters From below use the 4 screws 12f M6 x 10 provided to fix the hood body to the frame 12f 12c 12c ELECTRICAL CONNECTION Connect the hood to the mains through a two pole switch hav ing a contact gap of at least 3 mm Remove the grease filters see paragraph Maintenance being sure that the connector of the feeding cable is ...

Page 10: ...n the button is pushed for about 2 seconds After 10 minutes of functioning it turns off automatically This function can be interrupted by means of pressing any of the buttons S1 Led Fixed Indicates that the Metal grease filters saturation alarm has been triggered and the filters need to be washed The alarm is triggered after 100 working hours Reset check the Maintenance paragraph Flashing indicate...

Page 11: ...et Switch off the lights and extractor motor Press button T3 for at least 3 seconds until the leds start to flash Cleaning the filters The filters are washable and must be cleaned when the LED S1 lights up or at least every 2 months of operation or more frequently for particularly heavy usage Remove the filters one at a time by pushing them to wards the back of the group and pulling down at the sa...

Page 12: ...tion LED flashes twice Activated charcoal filter saturation alarm ENABLED LED flashes once Activated charcoal filter saturation alarm DISABLED Replacing the activated charcoal filter Alarm signal reset Switch off the lights and extractor motor Press button T3 for at least 3 seconds until the leds start to flash Replacing the Filter Remove the metal grease filters Remove the saturated activated car...

Page 13: ...t recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin dass dieses Produkt nicht als normaler Haushaltsabfall zu behandeln ist sondern an einem Sammelpunkt für das Recycling von elektrischen und elektronischen Geräten abgegeben werden muss ...

Reviews: