50
Installation
Mounting accessories included
4 wall plugs Ø 8 mm (brick fixing only)
4 wood-screws 5 x 45 mm
2 hooks
1 allen spanner
Wall unit mounting - Fig. 8
Trace the symmetry axis, position the
perforation template (1) on the wall and mark
the two holes to make, then make the holes (2 x
Ø 8 mm)
(2)
.
Insert the two dowels into the wall with hooks
(3)
.
Open the upper cover temporarily to get to the
hooking area of the hood (4).
If you want to install a telescopic flue (to order,
see special accessories), the upper cover must
be completely removed (in this case release the
electrical cable and the core hitch from the
cover).
Attach the hood and adjust its horizontally using
the adjustment screws
(5)
.
Remove the metal filters
(6)
and mark two
holes on the wall
(7).
Release the hood and
make the two holes previously marked (2 x Ø 8
mm).
Insert the wall dowels into the two holes
(8)
and hang the hood up again; adjust it using the
screws
(9)
and fix the hood definitively with the
supplied screws
(10).
Aspiration
version (S)
:
a.
if installed,
remove the deflector from the
exit hole
(11a)
.
b.
insert the tube between the exit hole and the
wall drawer or the attachment to the wall/
ceiling
(11b)
.
Filtering
Version (K)
: if not already installed,
apply the deflector as cover of the exit hole
(11c)
.
Put the upper cover back in its place again.
Connect the electrical connection
(12)
(see
Electrical connection chapter).
1
2+3
4
4
6
7
7
8
8
10
10
9
9
5
12
S
K
11c
11a
11b