Installation

Wall unit mounting - Fig. 7

Disconnect the hood during electrical connection, by turning the home mains switch off.

Remove the 2 screws fitted inside the lower part of the hood at the points in which it is

fixed to the motor unit  (see also operation 3).

•

Rest the motor unit on a flat

surface and thread the lower part

of the chimney section onto it

 (1)

.

•

Make all the electrical

connections between the two

parts

 (2)

.

•

Secure the two parts using 8

screws 

(3)

.

• Mark the wall with a centre line, this

will aid the fixing procedure 

(4)

, position

the template so that the mid line printed on

the template matches with the centre line

previously marked, the lower side of the

template corresponds to the lower side of

the hood once installed 

(5)

.

• Drill two holes Ø 8mm and fix the support

bracket with two wall plugs and screws

(6)

.

• Hang the hood 

(7)

 adjust its position 

(8-9)

and from the inside of the hood mark one

point for final fixing 

(10)

, remove the hood

(11)

 and drill an hole Ø 8mm 

(12)

, fit a

wall plugs 

(13)

.

• Drill two holes Ø 8mm on the upper side

close to the ceilling 

(14)

, fit two wall

plugs and fix the chimney support

with two screws 

(15)

.

• Hang the hood again

 (16)

.

• Fix it securely with a screw

(17)

. To simplify the

installation operation

remove the charcoal filter

frame.

• If the hood is used in the

recirculation function

, fix

the deflector 

F

 on the

chimney support 

G

 with 2

screws and fit an extraction

pipe 

(18 

- not supplied

)

 to connect deflector to the outlet hole 

D

 of the hood.

In case the hood is to be used in exhausting version, then the deflector must not be

mounted and fit an extraction pipe 

(18)

 to connect outlet hole 

D

 of the hood to the

outside.

• Make the electrical connection 

(19)

, but leave the hood disconnected from the

household mains supply.

• Fix the chimney 

(20a)

 to the chimney support 

(20b)

.

Slide down the lower section on the proper housing on top of the hood. Connect the hood

to the household mains supply and check that the hood works correctly.

Fig. 7

Summary of Contents for EFC 9440

Page 1: ...Gebrauchsanweisung Noticed utilisationetd installation Installatie engebruiksaanwijzing EFC 9440 F NL D Usermanual Instruccionesdemontajeymanejo ManualdeInstruções UK P E ...

Page 2: ...nstruction manual and keep it available at use of the cooker hood Safety warnings 32 For the installer 32 For the user 33 Description of the Appliance 34 Extraction 34 Recirculation 34 Control Panel 34 Maintenance and care 35 Cleaning the hood 35 Metal grease filter 35 Removing the metal grease filter 35 Charcoal filter 36 Changing the light bulb 36 What to do if 37 Special accessories 37 Technica...

Page 3: ...al and regional building regulations impose a number of restrictions on using hoods and fuel burning appliances connected to a chimney such as coal or oil room heaters and gas fires in the same room Hoods can only be used safely with appliances connected to a chimney if the room and or flat air environment combination is ventilated from outside using a suitable ventilation hole approxi mately 500 ...

Page 4: ... The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance WARNING Ensure that the appliance is switched off before replacing the lamp to avoid the possibility of electric shock This appliance is marked according to the European directive 2002 96 EC on Waste Electrical and Ele...

Page 5: ... on after cooking for about 15 minutes or until all the odours have disappeared The control switches are located on the unit s front panel Light switch this switch is used to turn the light fitted in the hood on and off Extractor fan switch used to turn the fan off Push button 1 used to set the fan to speed 1 Push button 2 used to set the fan to speed 2 Push button 3 used to set the fan to speed 3...

Page 6: ...grease filters is to absorb grease particles which form during cooking and it must always be used either in the external extraction or internal recycling function Attention the metal grease filters must be removed and washed either by hand or in the dishwasher every four weeks Removing the metal grease filter First push the metal grease filter stop f1 backwards then extract the filter f2 pulling d...

Page 7: ...ith a temperature of maximum 100º C After approximately three years of use the carbon filter should be replaced with a new as the odour reduction capacity will be reduced Fitting Remove the frame i which supports the filter h by turning 90 the two knobs g Insert the charcoal filter inside the frame and put all parts back in their place Fig 4 To remove proceed in the reverse order Always specify th...

Page 8: ...utlets are not blocked The cooker hood has The safety cut out device has been tripped switched off during operation Turn off the hob and then wait for the device to reset If the hood has been installed below the heights indicated in the installation instructions the motor will cut out frequently which will damage the hood If after all these checks the problem persists contact your local Service Fo...

Page 9: ...tically routed to the Service Centre covering your post code area For the address of your local Service Force Centre and further information about Service Force please visit the website at www serviceforce co uk Please ensure that you have read the section What to do if as the engineer will make a charge if the fault is not a mechanical or electrical breakdown even the appliance is under warranty ...

Page 10: ...sary to provide a fixed connection the hood must only be installed by an electrician authorised by the local electricity board When installing an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided Fixed connection of the appliance must only be carried out by an authorised electrician Electrical connection for UK only Safety warnings for the electrician Connec...

Page 11: ... to the support 1 reduction flange Ø 125 120 mm Only for model EFC 9460 X 942 120 705 1 support bracket 5 wood screws 5 x 45 mm for wall mounting 5 wall plugs Ø 8 mm for wall mounting 2 metal screws 2 9 x 6 5 for chimney flue mounting 6 metal screws 4 x 20 to affix the screen to the cooker hood 1 allen spanner for TORX 10 20 screws ...

Page 12: ...hood 7 adjust its position 8 9 and from the inside of the hood mark one point for final fixing 10 remove the hood 11 and drill an hole Ø 8mm 12 fit a wall plugs 13 Drill two holes Ø 8mm on the upper side close to the ceilling 14 fit two wall plugs and fix the chimney support with two screws 15 Hang the hood again 16 Fix it securely with a screw 17 To simplify the installation operation remove the ...

Page 13: ...er of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world Electrolux 2003 ...

Reviews: