Rocker 1 =

To switch the right and the left halogen lamp on and off 

Rocker 2 =

To switch both halogen lamps in the front and both 
halogen lamps in the beck on and off 

Rocker 3-5 =

To switch the different power levels 
Power 1 = low step 
Power 2 = medium step 
Power 3 = high step 

Pushbutton 6 =

After-running 1 = 30 minutes 

Pushbutton 7 =

After-running 2 = 60 minutes

LED mains (green) 

Device is ready for operation 

LED fan (red) 

Motor is running 

LED

(yellow)

=

Disinfection lamp and ionizer are in operation 
(lit up all the time while the motor is running respectively 
only when the motor is running) 

Disinfection lamp (14) and ionizer start operating automatically when the motor is switched on. They
cannot and do not need to be switched on and off separately. 

After running: 
Please hold the after running rocker depressed for at least 2 seconds in order to be able to assure the
desired after running time. 

6. Exchanging halogen reflector lamps (13)

Pull out defect halogen lamps (13) and press new lamps into the socket! Do not pry out defect halogen
lamps using metal parts (e.g. screwdriver or knife) since thereby the hood body could be damaged. 

7. Taking out metal filters with Ionizer sheet (7) 

Before taking out metal filters, it is imperative to disconnect the device form the mains power supply by
turning off main switch (17)! 

When removing the upper filter (7) the following must be regarded: 

To also enable cleaning of the ionizer sheet, it is necessary to detach the supply cable from each filter
when removing the filters. To do so just pull cable off (see photographs below). 

      

Supply cable is detached from 

View after taking out 

the ionizer sheet 

metal filter 

Page 7

Summary of Contents for EFC 9020X

Page 1: ...EFC 9020X Air purification center Wall mounted With cord suspension Installation and operating instructions Status 03 2008 ...

Page 2: ... disc 13 Halogen lamps 20 watt EKL 5 Hanger bolt 14 Disinfection lamp UV C lamp EKL 6 Dowel 15 Stainless steel carbon filter 586 x 324 mm 7 Metal filters with ionizer sheet 16 Starter for UV C lamp with spring locking 17 Main switch 8 Cable for ionizer sheet 18 Retainer for cable suspension 9 Wall fixing rail Page 2 ...

Page 3: ...shes under the exhaust hood The open flame could cause a fire Never leave the pan unattended when you deep fry food because the grease could catch on fire Constant maintenance assures unobjectionable operation and maximum performance of your exhaust hood All dirty surfaces should be regularly cleaned and cleared from deposits The filter must frequently be removed and cleaned Wrong halogen lamps 13...

Page 4: ...8 mm dowels out of the by pack kit and stick them into the drilled holes 6 Take the wall fixing rail off from the rear side of the hood by unscrewing the three screws on the topside of the hood 7 Now fasten the wall fixing rail using five 5 x 50 mm round head screws from the by pack kit 8 For the cable suspension you have to copy two drill holes onto the ceiling See Sketch 2 9 Now drill the two 10...

Page 5: ...Figure 1 Figure 2 Figure 3 Figure 4 Page 5 Sketch 1 Hole pattern for drill holes wall Sketch 2 Holes ceiling for cable suspensions ...

Page 6: ...ainless steel filter 586 x 324 mm 15 into the hood body 1 Close grease collecting pan 12 Switch on main switch 17 on top of the device LED mains indicator is lit up green The appliance is now ready for operation UV C lamp 14 with Main switch UV C lamp 14 without protective cardboard protective cardboard Hood body 11 with Stainless steel carbon filter 15 5 Operation 7 rocker control Page 6 Heat det...

Page 7: ...nd off separately After running Please hold the after running rocker depressed for at least 2 seconds in order to be able to assure the desired after running time 6 Exchanging halogen reflector lamps 13 Pull out defect halogen lamps 13 and press new lamps into the socket Do not pry out defect halogen lamps using metal parts e g screwdriver or knife since thereby the hood body could be damaged 7 Ta...

Page 8: ...ry and a moist cloth Filters Caution With increasing saturation by greasy deposits flammability increases and functioning of the device may be impaired Clean metal filters 7 15 in due time Before cleaning it is imperative to remove the activated carbon attachment and knurled screws At normal operating conditions 2 to 3 hours daily the metal grease filter 7 15 needs to be cleaned every 8 to 10 week...

Page 9: ...must be cleaned Furthermore you should check if the connector of the supply cable is connected to the ionizer sheet horizontally In case of undervoltage it can happen in power step 1 that the interconnecting relay for the ionizer and for the UVC lamp switches on and off several times flips You can eliminate this by shortly activating power step 3 Hood cannot be switched on Check if all filters are...

Page 10: ...111 Your call will automatically be routed to your closest service location Please be at home when the service technician comes since he is dependent on your information 11 Spare parts accessories Activated carbon refill pack 1 kg A No 407 14 38 29 7 Filter cleaning agent Flamil 50 Super 200 ml A No 407 14 38 30 5 Stainless steel cleaner 200 ml A No 407 14 38 31 3 12 Quality control These devices ...

Page 11: ...13 Warranty customer service Page 13 ...

Page 12: ...by cleaning the upper metal filters 3 on a regular basis Using the ionizer is not hazardous Even from high dose of negative ions doesn t do you any harm A high dose of positive ions however can make you sick tired slackly sometimes even irritated and aggressive Information regarding the disinfection radiator 14 This disinfection radiator is a special low pressure mercury vapor radiator emitting sh...

Page 13: ...ellow human beings health Environment and health are being jeopardized by incorrect disposal Additional information about the recycling of this product you will get at your city hall your garbage collection office or at the shop where you had bought this product Where to dispose of the old appliances Everywhere where new appliances are sold or delivering up at the official S EN S collection points...