background image

30

Safety warnings

For the installer

When used as an extractor unit, the hood must
be fitted with a 120mm diameter hose.

When installing the hood, make sure you
respect the following minimum distance
from the top edge of the cooking hob/ring
surfaces:
electric cookers

600 mm

gas cookers

750 mm

coal and oil cookers

800 mm min.

The national Standard on fuel-burning systems
specifies a maximum depression of 0.04 mbar in
such rooms.

The air outlet must not be connected to chimney
flues or combustion gas ducts. The air outlet
must under no circumstances be connected to
ventilation ducts for rooms in which fuel-burning
appliances are installed.

The air outlet installation must comply with the
regulations laid down by the relevant authorities.

When the unit is used in its extractor version, a
sufficiently large ventilation hole must be
provided, with dimensions that are approxi-
mately the same as the outlet hole.

National and regional building regulations
impose a number of restrictions on using hoods
and fuel-burning appliances connected to a
chimney, such as coal or oil room-heaters and
gas fires, in the same room.

Hoods can only be used safely with appliances
connected to a chimney if the room and/or flat
(air/environment combination) is ventilated from
outside using a suitable ventilation hole approxi-
mately 500-600 cm

 large to avoid the

possibility of a depression being created during
operation of the hood.

If you have any doubts, contact the relevant
controlling authority or building inspector’s
office.

Since the rule for rooms with fuel burning
appliances is “outlet hole of the same size as the
ventilation hole”, a hole of 500-600 cm

2

, which

is to say a larger hole, could reduce the perfor-
mance of the extractor hood.

If the hood is used in its filtering function, it will
operate simply and safely in the above
conditions without the need for any of the
aforementioned measures.

When the hood is used in its extractor function,
the following rules must be followed to obtain
optimal operation:

— short and straight outlet hose
— keep bends in outlet hose to a minimum
— never install the hoses with an acute angle,

they must always follow a gentle curve.

— keep the hose as large as possible

(preferably the same diameter as the
outlet hole).

Failure to observe these basic instructions will
drastically reduce the performance and increase
the noise levels of the extractor hood.

For the user

The cooker hood is designed to extract
unpleasant odours from the kitchen, it will not
extract steam.

Always cover lighted elements, to prevent
excess heat from damaging the appliance.  In
the case of oil, gas and coal fired cookers it is
essential to avoid open flames.

Also, when frying, keep the deep frying pan on
the cooker top/cooker under careful control.

The hot oil in the frying pan might ignite due to
overheating.

The risk of self-ignition increases when the oil
being used is dirty.

It is extremely important to note that
overheating can cause a fire.

Never carry out any flambé cooking under
the hood.

Always disconnect the unit from the power
supply before carrying out any work on the
hood, including replacing the light bulb
(take the cartridge fuse out of the fuse holder or
switch off the automatic circuit breaker).

It is very important to clean the hood and
replace the filter at the recommended
intervals. Failure to do so could cause
grease deposits to build up, resulting in a
fire hazard.

The appliance is not intended for use by young
children or infirm persons without supervision.

Young children should be supervised to ensure
that they do not play with the appliance.

WARNING - Ensure that the appliance is
switched off before replacing the lamp to avoid
the possibility of electric shock.

Summary of Contents for EFC 640

Page 1: ...Gebrauchsanweisung Notice d utilisation et d installation EFC6410 6405 9410 9405 650 950 CH1200 900 600 F I D Istruzioni per l uso User manual UK ...

Page 2: ...chnical assistance service 36 GUARANTEE CONDITIONS 37 Installation 38 Unpacking 38 Placement 38 Electrical connection 38 Wall unit mounting 39 UK Before you use the cooker hood we recommend that you read through the whole user manual giving a direct description of the cooker hood and its functions To avoid the risks that are always present when you use a product driven by electricity it is importa...

Page 3: ...s used in its filtering function it will operate simply and safely in the above conditions without the need for any of the aforementioned measures When the hood is used in its extractor function the following rules must be followed to obtain optimal operation short and straight outlet hose keep bends in outlet hose to a minimum never install the hoses with an acute angle they must always follow a ...

Page 4: ...ters are attached to one of the side polystyrene protection panels and should be mounted prior to using the cooker hood in the filter version Extractor version In this version fumes are extracted to the outside via a hose connected to the coupling ring Fig 1 In order to obtain the best performance the hose should have a diameter equal to the outlet hole Fig 1 Filter Version The air is filtered thr...

Page 5: ...t 15 minutes or until all the odours have disappeared The control switches are located on the unit s front panel Correct ventilation If the cooker hood is to work correctly there must be an under pressure in the kitchen It is important to keep the kitchen windows closed and have a window in an adjacent room open Light switch Motor switch ON OFF Light button OFF Motor button Speed 1 button Speed 2 ...

Page 6: ...n the dishwasher every four weeks Removing the metal grease filter Push it towards the back of the unit and then pull it down and out Fig 3 Hand washing Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the process if necessary Refit the grease filters when they are dry Dishwasher Place grease filters in the dishwash...

Page 7: ...eplacement filters This information is shown on the registration plate located on the inside of the unit The charcoal filter can be ordered from your local ELECTROLUX Service Force Centre Changing the light bulb Disconnect the cooker hood from the main supply Remove the lamp cover Replace the old bulb with a new one of the same type Remount the lamp cover If the light does not come on make sure th...

Page 8: ...s contact your local Service Force Centre quoting the model and serial number Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown Special accessories Charcoal filter KF825 E Nr 942 118...

Page 9: ... and further information about Service Force please visit the website at www serviceforce co uk Please ensure that you have read the section What to do if as the engineer will make a charge if the fault is not a mechanical or electrical breakdown even the appliance is under warranty Please note that proof of purchase is required for in guarantee service calls Help us to help you Please determine y...

Page 10: ...ic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the European Community EC or European Free Trade Area Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacture which are not marketed by Electrolux European Guarantee If you should move to anothe...

Page 11: ...lug can be connected to any standard power socket within easy access Should it be necessary to provide a fixed connection the hood must only be installed by an electrician authorised by the local electricity board When installing an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided Fixed connection of the appliance must only be carried out by an authorised e...

Page 12: ...definitively with 2 4 screws 5X45 7 Fix the chimney support 8 with two screws 5 x 45 mm and two wall dowels on the wall close to the ceiling For exhausting version Fit the connection ring S on the top of the hood with two screws Ø 3 5 x 6 5 mm 9S then fit an axhausting pipe long enough to reach the outside 10S For recycling version Fix definitively the deflector K on the top of the hood with two s...

Page 13: ...LI1AQB Ed 12 02 ...

Reviews: