![Electrolux EDW 1500 - 1510 Service Manual Download Page 37](http://html.mh-extra.com/html/electrolux/edw-1500-1510/edw-1500-1510_service-manual_91984037.webp)
SOI/TD - PR
37
599 36 01-86
12 QUICK GUIDE TO THE SPECIAL FUNCTIONS
The table below briefly describes how each of the special functions available to the user and to the Service Engineer can be used.
Function
Activation of the function
Starting the function
Brief description / Comments
Buttons
Led(s)
Buttons
Display
Select regeneration
S0
(On/Off)
[
S2
+
S3
]
LD1
+
LD2
+
LD3
flashing
S1
LD1 flashes
1L ..... 10L
(description on page 24 / chapter 6.14). Press S1:
Liv….[
1L
]……[
2L
]….[
3L
]…...[
4L
]……[
5L
]…. [ 6L
]…...[
7L
] .…[
8L
]……[ 9L]….…[10L]
°F… >8 ….. >14 ..…>20 ….. >30 ….. >40 ….. >50 ….. >60 ….. >70 ….. >80 ….... >90
°D… >4 …... >8 ..…. >11 ..... >17 ….. >22 ….. >28 ….. >33 ….. >39 ….. >45 ……. >50
Disactivate
rinse-aid
S0
(On/Off)
[
S2
+
S3
]
LD1
+
LD2
+
LD3
flashing
S2
LD2 flashes
0d / 1d
(description on page 22 / chapter 6.10)
Press S2 and press again: 1d = rinse-aid activated, 0d = not activated
U
S
E
R
(
*)
Disactivate buzzer
S0
(On/Off)
[
S2
+
S3
]
LD1
+
LD2
+
LD3
flashing
S3
LD3 flashes
0b / 1b
(description on page 11 / chapter 4.6.1)
Press S3 and press again: 1b = buzzer activated, 0b = not activated
Display of alarms
and components
diagnostics
[
S1
+
S3
]
S0
(On/Off)
LD1
+
LD2
+
LD3
flashing
S1
LD1 flashes
i_0 / 4......10
flashing
(description on page 29 / chapter 10.2).
Press button
S1:
[i.0] [i.0] [i.0] [
4
] [
5
] [
6
] [ 7
] [
8
] [ 9
] [10]
AL 1
AL2
AL 3
ER
PS
EV
RR
PL
DD
MV
Cancel alarms
stored in memory
[
S1
+
S3
]
S0
(On/Off)
LD1
+
LD2
+
LD3
flashing
S2
[
188
]
(description on page 30 / chapter 10.3)
All the LEDs and digits flash for 30 sec.
Test cycle
[
S1
+
S3
]
S0
(On/Off)
LD1
+
LD2
+
LD3
flashing
S3
LD3 flashes
[
50
]
Time-to-end
(description on page 30 / chapter 10.4)
The cycle starts automatically
Extra rinse
[
S1
+
S3
]
S0
(On/Off)
LD1
+
LD2
+
LD3
flashing
[
S1
+
S2
]
S1
LD1 flashes
0A / 1A
flashing
(description on page 31 / chapter 10.5.1)
Press S1 and press again: 1A = rinse activated 0A = not activated
S
E
R
V
IC
E
E
N
G
IN
E
E
R
S
Disable buttons
[
S1
+
S3
]
S0
(On/Off)
LD1
+
LD2
+
LD3
flashing
[
S2
+
S3
]
S2
LD2 flashes
0P / 1P
flashing
(description on page 31 / chapter 10.5.2)
Press S2 and press again: 1P = pulse wash PW activated;
0P = continuous wash
Exit / Memorize
In order to memorize the functions or exit diagnostics mode, press key
S0
to switch the appliance off
(
On/Off). In most cases, memorization / exit take place
automatically after 60 seconds (in which case the appliance returns to pre-selection mode).
(*)
To activate the functions available to the user, no cycles must be selected (i.e. the appliance must be in pre-selection mode).