SOI/ADL 2009-10
6/63
599 72 40-73
5
Higher-power (1400W) heating element.
Motor triac for ventilation.
Door closed. Max.
time 10 min.
Heater unit (half
power).
6
Both branches of the heater unit.
Motor triac for ventilation.
Door closed. Max.
time 10 min.
Heater unit (full
power).
7
Conductimetric sensor. This check has duration
of 4 sec. (
1 sec. to create the short circuit
).
The phase/warning LEDs flash during this
period. If the result is correct at the end, the
LEDs remain lit; if not, the LEDs flash and alarm
E32
is displayed.
Door closed.
Short circuit
between the two
drum shells
.
Control of the
conductimetric sensor
when shortcircuited.
8
Conductimetric sensor. This check has duration
of 4 sec. The phase/warning LEDs flash during
this period. If the result is correct at the end, the
LEDs remain lit; if not, the LEDs flash
continuously.
Door closed.
Control of the
conductimetric
sensor when the
circuit is open.
9
Door opening Triac. After 2 attempts, if the door
does not open, an alarm is displayed.
Coil of the door interlock.
Door closed
After two seconds
the triac activates.
Operation of the door
opening
10
Floating switch.
Canister fill pump.
Door closed
Tempo max. 30
sec.
Operation of the
floating switch (sump
empty)
11
Reading/cancellation of the last alarm code
Turn the knob till position 11, paying attention
not to stop at position 7, because error
E32
may
occur.
---
---
12-13-14-15
All the LEDs light in sequence.
When a button is pressed, the corresponding
LED lights and the buzzer sounds.
Always activated
Operation of the user
interface.
2 Allarms
2.1 ALARMS EDR 1000
2.1.1 Displaying the alarms to the user
Operation of the alarms is configurable according to the model. Some or all of the alarms may be
displayed to the user.
Normally, all alarms except E44, E52, E63, E94, EB2 are displayed to the user.
When an alarm condition occurs, the drying cycle may be interrupted or paused; in some cases, for the sake
of safety, a forced cooling cycle is performed. In this case, the electronic board, if possible, disconnects the
power relay from the heater unit and powers the motor of the drum cooling fan. The cycle remains active until
the user switches off the appliance.