13.4 Electrical connection
WARNING!
If service is required always
disconnect the appliance
from the power supply.
Use a power cable of H05VV-F or higher.
Install the appliance with a socket supply
line. If there is no socket supply line, the
fixed home electrical system must
include an isolating device with at least a
3 mm-contact separation to enable a
simultaneous and all-pole cut off from the
mains (according to NIN SEV 1000). The
customer must have a socket for the
electrical connection that is accessible
and outside the coordination room. The
length of the connection cable must be
approximately 120 cm with lines
connected directly to the mains.
Only a qualified person can
connect the appliance to the
electricity supply.
1. Do the electrical connections as in
the connection illustration.
Phase definitions: L1, L2, L3 (or R, S,
T).
L2 L3
400V
L1
PE
L2
400V
L1
PE
1
2
3
4
5
1
2
3
4
5
400V 2N~
400V
400V
400V 3N~
N
N
2. Secure the cable grip.
1
2
3
4
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
1
2
3
4
www.electrolux.com