![Electrolux Dishwashing EUC1 User Manual Download Page 5](http://html.mh-extra.com/html/electrolux/dishwashing-euc1/dishwashing-euc1_user-manual_91949005.webp)
7
ENGLISH
Install a disconnecting switch with a capacity at
least equal to that given in the technical data table,
a 30mA residual current circuit breaker and an
overcurrent device (magnetothermal cut-out with
manual reset or fuse) between the appliance and
the mains power outlet.
The chosen device must be lockable in the open
position in case of maintenance.
RATING PLATE
The rating plate contains identification and technical
data and is located on the right-hand side panel of the
appliance (Figure 5).
Figure 5
B1
WATER CONNECTION
CAUTION
Watermark labelled machines must be installed in
accordance with AS/NZS 3500.1.
If the dishwasher is installed under a worktop, make
sure the dimensions of the space in which it is placed
match those given in Figure 6.
Figure 6
Position the dishwasher and level the appliance by
turning the relative height-adjustable feet (Figure 5).
If the dishwasher is installed on a suitable support (e.g.
worktop); proceed as follows:
-
Access the bottom of the machine and unscrew the
4 feet.
-
Make four ø 9mm though holes in the support, res-
pecting distances given in Figure 7.
Figure 7
-
Place the dishwasher on the support, matching the
holes just made with the seats of the feet in the
bottom of the machine (Figure 8).
-
Secure the dishwasher with M8 screws.
Figure 8
•
Connect the appliance water supply pipe “A”
(Figure 4) to the mains, fitting a cut-off valve, the fil-
ter provided and a pressure gauge between the
appliance and the mains (Figure 9).
•
In NUC1G / EUC1G models, connect the double
non-return valve "B" (Figure 9) supplied and the
machine supply pipe.
Figure 9
•
Check that the
dynamic
water supply
pressure
,
measured between the appliance and the main, is
between 200 and 300 kPa
for machines with pres-
sure boiler and
between 50 and 700 kPa
for
machines with atmospheric boiler (test while dish-
washer tank or boiler is filling with water).
If the pressure is too high, fit a suitable pres-
sure reducer on the inlet pipe.
B INSTRUCTIONS FOR THE INSTALLER/MAINTENANCE PERSON
Model LS5
PNC 9CGX 400100 05 Ser.N .123000001
AC 400V 3N 50Hz
Power Boiler 16500w
Power Tank 7500w
Power Max 26800w
Made in EEC
Model RT10 ED
PNC 9CGX400100 05
Ser.N .123000001
8
70
4
3
1 mm
50
8
mm
!
B