Operation

Controls

Dead-front mode

IMPORTANT

The HEAT SENTRY thermostat can start the
blower even if the hood is turned OFF. When
this occurs, it is impossible to turn the blower
OFF with its switch. If you must stop the blower,
do it from the integral disconnecting switch
located inside the blower housing.

Stand-by mode

In dead-front mode, press any key for enter in stand-
by mode.
If the hood is in stand-by mode, after 10 seconds on
return automatically in dead-front mode.

Light switch
Press any key for enter in stand-by mode.
Push the light switch once to turn the lights ON to a
dim level.
Push a second time to turn the lights ON to a brighter
level.
Push a third time to turn the lights OFF (stand-by
mode).

Fan speed switches
Press any key for enter in stand-by mode.
The fan speed switches turns the fan on.
1 : fan ON at low speed
2 : fan ON at medium-low speed
3 : fan ON at medium-high speed
4 : fan ON at high speed

Fan on/off switch
Push this fan switch to turn OFF the fan.
The hood turns in the stand-by mode.

Delay shut off switch
Pressing this switch when is active any speed, sets a
timer which keeps the fan operating at this speed for
10 minutes (the number “10” appears in the display).
After 10 minutes, the hood turns in the stand-by mode.

Heat Sentry active

Push this switch once to turn the timer Off.

Filter reset switch
When the filter switch is illuminated, it is necessary to
clean the GREASE FILTERS. Once the grease filters
are cleaned and installed, press in and hold the “filter
reset switch” for approximately 3 seconds.
When the filter switch is illuminated and blink, it is
necessary to replace the CHARCOAL  FILTER. Once
the new charcoal filter is installed, press in and hold
the “filter reset switch” for approximately 3 seconds.

Heat Sentry
Your hood is equipped with a HEAT SENTRY™
thermostat. This thermostat is a device that will turn
on or speed up the blower if it senses excessive heat
above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns
blower up to HIGH speed.
When the Heat Sentry is active, the word “HS” appears
in the display and the tone alarm is active. To disarm
the tone alarm, press the 4 fan speed switch.
When the temperature level drops to normal, the blower
will return to its original setting.

light

switch

fan speed

switches

delay
shut

off

display

filter
reset

switch

fan

on/off

switches

Summary of Contents for DFKTWC75GS

Page 1: ...Use Care Guide Installation Instructions Vent Hood 316495007 09 2007 ...

Page 2: ...2 ...

Page 3: ...nhances our ability to serve you You can register online at www electroluxusa com or by dropping your Product Registration Card in the mail Questions For toll free telephone support in the U S and Canada 1 877 4ELECTROLUX 1 877 435 3287 For online support and Internet product information visit http www electroluxusa com Table of contents Finding information 3 SAFETY 4 Verify package contents 6 Ins...

Page 4: ... in accordance with all ap plicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Fol low the heating equipment manufacturer s guide lines and safety standards such as those published by the National Fire Protection Associat...

Page 5: ...oduce flames under the Range Hood 4 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 5 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 6 Your hood motor has a thermal overload which will automatically shut off the motor if it becomes over heated The motor will restart when ...

Page 6: ... Head 7 Mounting Screws 3 9 x 9 5mm Pan Head 2 Mounting Screws 3 9 x 6mm Flat Head 6 Drywall Anchors 2 Grease Filters 1 Installation Instructions 1 Warranty Card MOUNTING BRACKET DISCHARGE COLLAR FLUE MOUNTING BRACKET 6 MOUNTING SCREWS 4 8 x 38mm Pan Head 6 DRYWALL ANCHORS 7 MOUNTING SCREWS 3 9 x 9 5mm Pan Head DECORATIVE FLUE 2 MOUNTING SCREWS 3 9 x 6mm Flat Head Verify package contents GREASE FI...

Page 7: ...ork back towards hood location Use duct tape to seal the joints between ductwork sections 5 Never make the size or area of the ductwork smaller than the size that originates at the hood 6 Bigger ductwork is better 7 Keep duct lenght less than 50 linear feet 8 Minimize use of elbows and transitions 4 or less 9 Always separate 90 degree elbows with at least 2 feet of straight ductwork 10 Place trans...

Page 8: ...codes Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exists as to whether the appliance is properly grounded Do not use an extension cord If the power supply cord is too short have a qualified electrician install an outlet near the appliance Set the electrical power supply within the ...

Page 9: ... framing within the dimensions shown 2 After wall surface is finished secure mounting bracket to framing using dimensions shown FLUE MOUNTING BRACKET 10 5 8 270 4 mm 3 9 x 6 mm FLAT HEAD BRACKET SCREWS Install flue mounting bracket DUCTEDANDNON DUCTED 1 Assemble the flue mounting bracket adjusting outside width as shown 2 Carefullycenterthemountingbracketdirectlyover the range hood location 3 Secu...

Page 10: ...late shown in Fig 2 must be removed remove the 4 screws of the back plate operating from the inside of the hood Fig 3 3 Remove the tape on the electrical system plate place the electrical system plate on the hood protect surface from electrical system plate using cardboard protection Fig 4 4 Remove the 2 screws of the back plate Fig 5 and discard the back plate FIG 4 ELECTRICAL SYSTEM PLATE PROTEC...

Page 11: ...ood Install the 5 to 6 adapter supplied with the Non Ducted Recirculation Kit Fig 7 2 Secure the plenum to the flue mounting bracket with 2 3 9x6mm flat head screws the screws are supplied with the Non Ducted Recirculation Kit DFKTWC75GS Fig 8 FIG 7 3 9x6mm FLATHEAD SCREWS PLENUM 5 6 ADAPTER NON DUCTEDCONFIGURATION NOTE The following materials must be purchased separately for non ducted recirculat...

Page 12: ...drywall anchors provided if wall studs or framing are not available Fig 9 4 Mount the electrical system plate attaching it with 3 3 9x9 5mm mounting screws Fig 10 5 On ducted hoods attach 6 round metal duct between the hood s blower collar and duct that leads to the outside location Fig 11 6 On non ducted hoods attach 5 round metal expandable duct between the 5 6 adapter on the hood and the connec...

Page 13: ...vents are exposed Install the flue with air vents up ROOMS WITH 10 FOOT CEILINGS Rooms with 10 foot ceilings require flue extension model EXWC75GS available from your local dealer 10 Discard the upper flue supplied with the product Replace it with the flue extension EXWC75GS 11 Raisetheupperflueuntilitsholesalignwithholesinthefluemountingbracket locatedonceiling Fig 14 12 Secure the flue with 2 3 ...

Page 14: ...remove the CHARCOAL filter push in on the front filter latch Pull the filter down to disengage the rear filter tabs 2 To install the CHARCOAL filter align the rear filter tabs with slots in the hood Push the filter up into place until the front latch snaps securely into the slot Make sure the filter is securely engaged after assembly 3 Install GREASE filters after charcoal filter is in stalled GRE...

Page 15: ...e appearance Cleaning tips O Hot water with soap or detergent is all that is usu ally needed O Follow all cleaning by rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks O For discolorations or deposits that persist use a non scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth O For stubborn cases use a plastic scouring ...

Page 16: ...which keeps the fan operating at this speed for 10 minutes the number 10 appears in the display After 10 minutes the hood turns in the stand by mode Heat Sentry active Push this switch once to turn the timer Off Filter reset switch When the filter switch is illuminated it is necessary to clean the GREASE FILTERS Once the grease filters are cleaned and installed press in and hold the filter reset s...

Page 17: ...WITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE To change bulbs 1 Open the cover by prying from the proper slots DO NOT ROTATE CAUTION BULB MAY BE HOT 3 Replace with a max 20W 12V Type T3 bulb G4 Base bulb Do not touch replacement bulb with bare hands If the bulb is touched with the bare hand it should be cleaned with a lint free cloth moistened with methylated...

Page 18: ...nt of light bulbs and or fluorescent tubes on models with these features This warranty does not cover the following 1 CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN OR ANY IMPLIED WARRANTY NOTE Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation or exclusion may not ap...

Page 19: ...19 ...

Page 20: ...04307838 3S ...

Reviews: