background image

SERVICE MANUAL

© Electrolux Distriparts

Fürther Straße 246
D-90429 Nürnberg
Germany

DGS-TDS-N

Publ.-Nr.:

599 714 137

685

12.08

EN

Edition:

COOKERS

Built-in hob

Interface

Kite 2

Summary of Contents for COOKERS Built-in hob

Page 1: ...SERVICE MANUAL Electrolux Distriparts Fürther Straße 246 D 90429 Nürnberg Germany DGS TDS N Publ Nr 599 714 137 685 12 08 EN Edition COOKERS Built in hob Interface Kite 2 ...

Page 2: ...3 1 Split interfaces for induction hobs 5 3 2 Split input electronics for hobs with radiant heating 5 3 3 Differentiation between the input electonics right left 6 3 4 5 zone input electronics for cooking hobs with radiant heating 6 4 Service Menue 7 4 1 Induction split input electronics UI 7 4 2 Radiant heated cooking hobs with split input electronics 8 4 3 Five zone input electronics 9 4 4 Error...

Page 3: ...c interface You also have to be careful with those electronics delivered as spare parts which have to be put out of the ESD protective package only after a potential compensation discharge of possible statical electricity If a potential compensation with an existing static electricity is not executed it does not mean that the electronic is demaged directly Consequential damages may result due to t...

Page 4: ...ft and right Bargraph light chain for displaying power level 2 2 Interface Kite Split with 7 Segment Display Variants Induction Radiant 230 V Radiant 400 V Definitions Kite Slider technology Split Interface left and right 7 S D 7 Segments to display 2 3 Interface Kite 5 zone Variants 7 Segment Display Bargraph Radiant Induction Definitions Kite Slider technology Split Interface left and right 7 S ...

Page 5: ... not matching to the interface functions are not available or the display of the 7 Segement Bargraph is not logic 2 5 Firmware The firmware is the software to control the interface independent on the configuration 3 Position of the input electronics 3 1 Split interfaces for induction hobs Induction coils Kite Split Silicone carrier 3 2 Split input electronics for hobs with radiant heating Kite Spl...

Page 6: ...interface the same The difference is the lasered on the top The lasered ANCs is near the timer display To make sure that the left and the right interface in places correctely one illuminated field is lasered with R for tight display and L 3 4 5 zone input electronics for cooking hobs with radiant heating Kite Split Silicone carrier Carrier HOC 2010 230V Power electronic ...

Page 7: ...left Control software Module left Power software Module right Control software Module right Stored Error Codes Hob is off Press On Off until displays are off again In split input electronics the firmware version is shown in both of the timer displays and has to be identical With pressing the Plus Key the last 3 stored Errors are displayed in serial mode If no failure is stored only E is diplayed U...

Page 8: ...ep No Demo mode active Demo mode active Display test Start Firmware Interface left and right Firmware Power board Stored Error Codes In split input electronics the firmware version is shown in both of the timer displays and has to be identical With pressing the Plus Key the last 3 stored Errors are displayed in serial mode If no failure is stored only E is displayed Service mode ...

Page 9: ...mode active Demo mode active Service mode Display test Start Power software Module left Firmware Power board Stored Error Codes In split input electronics the firmware version is shown in both of the timer displays and has to be identical With pressing the Plus Key the last 3 stored Errors are displayed in serial mode If no failure is stored only E is displayed ...

Page 10: ...or in the left zones Change induction module on the left side E7 E7 in Timer display E or in the right zones Change iduction module on the right side E8 Communication error with the power board 1 Check supply connection 2 Check wiring between interface and power board 3 Change induction module E9 Internal interface error Exchange interface with silicone carrier Error in the timer display Failure S...

Page 11: ...ace No displays after reset of mains No 5 Voltage on the bus 1 Check wirings 2 Exchange powerboard left Demo mode is active Remove demo mode in the service menue Relay for heater is defect Check if a click of the relay is to hear if not the power board is defect Radiant heater is not working Heater is defect Check the resistance of the heater with a multimeter The resistance need to be lower than ...