12
Model
EL1...
ZL1...
NL1...
VL1...
CL1...
CL1G
EL1G
ZL1G
NL1G
VL1G
EL1P6
EL1G6M
ELA1W
ELA1WP
ELA1P
CLA1G
ELA1G
NLA1G
ZLA1G
ELA1G6
Electric conduc-
tivity of water
μS/cm
< 400
< 400
< 400
< 400
< 400
< 400
Concentration of
chlorides in
water
ppm
< 20
< 20
< 20
< 20
< 20
< 20
Rinse cycle
water
consumption
l
3
3
3
3
3
3
Boiler capacity
l
5.8
5.8
5.8
5.8
5.8
5.8
Tank capacity
l
33
33
33
33
33
33
Standard cycle
time with water
supply at 50
℃
.
sec.
120 - 180
120 - 180
120 - 180
120 - 180
90 - 180
60 - 120
90 - 180
[Only for
model
ZL1GMS]
90 - 120 - 240
Legal noise level
Leq
3
dB(A)
LpA: 63dB - KpA: 1.5dB
Protection rating
IPX4
Power supply cable
H07RN-F
1.
If activated by software, coincidence of tank and boiler heating elements.
2.
Only for model ELA1P
3.
The noise emission values have been obtained according to EN ISO 11204.
F.2
Main technical characteristics for three phases appliances
Model
EL3...
ZL3...
NL3...
VL3...
EL3G
ZL3G
NL3G
VL3G
ELA3W...
ZLA3W...
NLA3W...
VLA3WG
ELA3GWP
ELA3G...
ZLA3G...
VLA3G...
ELA3GTL
EL3PO-
WAG
ZLA3
ELA3G6
ELA3GTL6
Supply voltage:
400V 3N~
400V 3N~
400V 3N~
400V 3N~
400V 3N~
230V 3~
Convertible to:
230V 3~
230V 1N~
230V 3~
230V 1N~
230V 3~
230V 1N~
230V 3~
230V 1N~
230V 3~
230V 1N~
400V 3N~
230V 1N~
Frequency
Hz
50
50
50
50
50
60
Max. power
kW
5.35 [7.35]
1
5.35 [7.35]
5.35 [7.35]
5.35 [7.35]
5.35 [7.35]
5.35 [7.35]
Boiler heating
elements
kW
4.5
4.5
4.5
4.5
4.5
4.5
Tank heating
elements
kW
2.0
2.0
2.0
2.0
2.0
2.0
Water supply
pressure
bar
[kPa]
2 [200]
3 [300]
2 [200]
3 [300]
0.5 [50]
7 [700]
0.5 [50]
7 [700]
0.5 [50]
7 [700]
0.5 [50]
7 [700]
Water supply
temperature
℃
50
50
50
10 - 60
10 - 60
10 - 60
50 [Only for
models
EL3PO-
WAG -
ZLA3]
Water supply
hardness
°f/°d/°e
14/8/10
max
14/8/10
max
48/27/33.7
max
14/8/10 max
14/8/10 max
14/8/10 max
Electric conduc-
tivity of water
μS/cm
< 400
< 400
< 400
< 400
< 400
< 400
Concentration of
chlorides in
water
ppm
< 20
< 20
< 20
< 20
< 20
< 20