4
17
Safety
The safety of our freezers is in accordance with recognised technological
standards and appliance safety legislation. We nevertheless feel that it is
important to acquaint you with the following safety guidelines:
Use for Intended Purpose
The freezer is intended for household use only. It is suitable for freezing
and storage of frozen food. The manufacturer assumes no liability for
damages occurring through improper operation or use of the appliance
for unintended purposes.
Alterations or changes to the freezer are not permitted for reasons of
safety.
If you use the freezer in a commercial application or for purposes other
than the freezing or frozen storage of foods, the manufacturer accepts
no liability for any damages which may occur.
Prior to initial start-up
check the freezer for transport damage. Do not under any
circumstances connect a damaged appliance! Please contact your
supplier in the event of damage.
Refrigerant
The refrigerant isobutane (R600a) is contained within the refrigerant
circuit of the appliance, a natural gas with a high level of environmental
compatibility, which is nevertheless flammable.
During transportation and installation of the appliance, be certain that
none of the components of the refrigerant circuit become damaged.
If the refrigerant circuit should become damaged:
avoid open flames and sources of ignition;
thoroughly ventilate the room in which the appliance is situated.
Safety for Children
Packaging materials (e.g. films, styrofoam) can be dangerous for
children. There is a danger of suffocation Keep packaging materials
away from children!
For appliances with lockable lids: Children playing could get locked in.
There is a danger of suffocation Keep the key out of the reach of
children and do not leave it near the appliance.
Symptom
The appliance is not
functioning, the green
power supply pilot
light is not illuminated.
The temperature
acoustic alarm sounds
and the red warning
light illuminates.
Possible cause
The mains plug is not
plugged in.
The power supply has
been interrupted:
power cut in the
supply network, faulty
fuse, socket or
another fault in the
household electrical
system.
Too large a quantity of
warm products has
been put in the
freezer.
The lid has been left
open for a long time.
Temperature is not
properly adjusted.
Appliance malfunction.
Remedy
Insert mains plug.
Mains malfunctions
are to be corrected by
an electrician.
Please consult the
section on Freezing.
Only leave the lid
open for as long as is
necessary.
Please consult section
on Temperature
Ajustment.
Keep the lid closed
and notify your local
AEG Service force
Centre.
Replace light bulb
Warning!
Electric shock hazard! Before changing the bulb, disconnect
the appliance from the electricity supply.
Light bulb specifications: 220-240 V, max. 15 W, socket: E 14
F
F
Pull out the mains plug to switch off the appliance.
F
F
Open the lid of the chest freezer. The light bulb can be found in the inner
lid.
F
F
With the help of a small screwdriver
remove the light cover downwards.
F
F
Exert pressure to remove the light glass
as shown in the drawing. Unscrew the
bulb, and replace it with a new bulb.
F
F
Restart the appliance again.