16
Electrical connections
Any electrical work required
to install this cooker and the
supply cable should be carried out
by a qualified licensed electrician,
in accordance with the current
regulations.
This cooker must be earthed.
The manufacturer disclaims
any responsibility should these
safety instructions not be carried
out.
Before any maintenance or
cleaning can be carried out, you
must DISCONNECT the cooker
from the electricity supply.
This cooker is designed to be
connected to a 230-240V AC, 50Hz
electrical supply.
To connect to the electricity supply,
use cable type H05 RR-F.
Before connection, make sure the
electricity supply voltage is the same
as that indicated on the rating plate.
The cooker is supplied with supply
cable incorporating a 10A plug.
Connect the plug to an appropriate
10A socket. Any electrical work for
example to install a 10A socket
must
be completed by a licensed
electrician.
If hard wiring to the mains is
required, an omnipolar interrupter
with a minimum opening of 3 mm
between contacts dimensioned to
the voltage and corresponding to
the regulations in force, should be
interposed between the appliance
and the supply.
The interrupter must not interrupt
the yellow-green earth cable.
After installation and connecting,
the cable must be placed so that it
cannot at any point reach a
temperature of more than 50°C
above the ambient temperature.
supply
cable
NO
After connection try out the heating
elements allowing them to function
for approximately 3 minutes.
If the supply cable is
damaged, the manufacturer or its
service agent or a similarly
qualified person must replace it
in order to avoid a hazard.