background image

Electrolux air-o-steam - level A

Combi LW 20 GN 1/1-electric

Internet: http://www.electrolux.com/foodservice

ECAA040

2009-09-21

Subject to change without notice

Supply voltage

400 V, 3N, 50/60

400 V, 3N, 50/60

230 V, 3, 50/60

Net weight - kg.

284

284

284

    electric

34.5

34.5

34.5

    cooking chamber

34

34

34

    auxiliary

0.8

0.8

0.8

    boiler

24

24

20

Power - kW

    height

1450

1450

1450

    depth

715

715

715

    width

460

460

460

Internal dimensions - mm

    height

1795

1795

1795

    depth

957

957

957

    width

993

993

993

External dimensions - mm

N° of programs

100

100

100

Automatic cleaning system

Multi Point Probe

Two-speed fan

Low temp steaming

Regeneration

Cook&hold

Humidity control

Convection/steaming

Steaming

Convection

    combi

250

250

250

    steam

130

130

130

    air-convection

300

300

300

Cooking cycles - °C

Runners pitch - mm

63

80

63

Number of grids

20

16

20

Power supply

Electric

Electric

Electric

TECHNICAL DATA

AOS201EAA1

267004

AOS201EAH1

267014

AOS201EAN1

267024

• air-o-clean: 4 different pre-set 
cycles to clean the cooking cell, 
according to the actual 
requirements. The cleaning 
system is built-in (no need for 
add-ons).
• Quick cooling: useful when 
passing to a type of cooking that 
requires a lower temperature than 
the previous one. It works 
automatically and manually.
• Manual injection of water in the 
cell.
• Automatic steam generator 
water draining with an automatic 
scale diagnosis system.
• HACCP management as 
standard: it allows the recording of 
the cooking programme according 
to H.A.C.C.P. standard (Hazard 
Analysis and Critical Control 
Points). 

PERFORMANCE
• air-o-clima: controls and 
displays the exact (single degree 
of accuracy) humidity degree of 
the oven atmosphere in hot air, 
combi and regeneration cycles. 
Air-o-clima measures physically 
the real humidity level inside the 
cooking cell and acts 
consequently according to the set 
value. With hot air cycles, 
air-o-clima also manages to 
exhaust the excess humidity 
generated by the food.
• air-o-flow: blows fresh air from 
outside through the bi-functional 
fan, which pulls the air in from the 
backside of the oven after it is 
pre-heated, thus guaranteeing an 
even cooking process.
• Multi-sensor food probe: 6 
sensors, ½ ºC accuracy.
 
CONSTRUCTION
• Stainless steel 304 throughout, 
with seamless joints in the cooking 
cell.

• Height adjustable legs.
• Double thermo-glazed door 
equipped with drip pans to catch 
condensate and prevent slippery 
floor for maximum security and 
four holding positions allowing 
easier loading and unloading.
• Halogen lighting in the cooking 
cell.
• Access to main components 
from the front panel.
• Automatic scale diagnosis 
system in the steam generator to 
detect the presence of scale 
build-up.
• IPX5 water protection.
• air-o-steam ovens meet IMQ 
safety requirements.
 

Summary of Contents for Air-O-Steam 267004

Page 1: ...oking Impressive reduction of cooking times and food shrinkage The humidity generated by the food and the steam generator can be controlled by air o clima with Lambda sensor for consistent results regardless of the food load air o steam ovens can cook by controlling either the cooking time or the product s core temperature through a 6 sensor probe Regeneration cycle it produces the best humidity c...

Page 2: ...injection of water in the cell Automatic steam generator water draining with an automatic scale diagnosis system HACCP management as standard it allows the recording of the cooking programme according to H A C C P standard Hazard Analysis and Critical Control Points PERFORMANCE air o clima controls and displays the exact single degree of accuracy humidity degree of the oven atmosphere in hot air c...

Page 3: ...922275 922275 922275 KIT HACCP EKIS 922166 922166 922166 HEAT SHIELD FOR 20 GN 1 1 OVENS 922243 922243 922243 FRYING GRIDDLE GN 2 3 FOR OVENS 922284 922284 922284 FRYING GRIDDLE GN 1 1 FOR OVENS 922215 922215 922215 EXTERNAL SIDE SPRAY UNIT 922171 922171 922171 DOOR SHIELD 20 1 1 PRE HEAT W O TROLLEY 922094 922094 922094 CONTROL PANEL FILTER 20 GN1 1 OVENS LW 922230 BASKET FOR DETERGENT TANK WALL ...

Page 4: ...09 09 21 Subject to change without notice WIC Cooling water inlet 3 4 3 4 3 4 EI Electrical connection 400 V 3N 50 60 400 V 3N 50 60 230 V 3 50 60 DO Overflow drain pipe D Water drain 1 1 4 1 1 4 1 1 4 CWI Cold water inlet 3 4 3 4 3 4 LEGEND AOS201EAA1 267004 AOS201EAH1 267014 AOS201EAN1 267024 267004 267024 267014 ...

Reviews: