Electrolux air-o-convect 20 GN Specifications Download Page 2

Electrolux air-o-steam

Combi lengthwise 20 GN 1/1-electric

Internet: http://www.electrolux.com/foodservice

ECA030

2007-05-02

Supply voltage

400 V, 3N,

50/60

230 V, 3, 50/60

400 V, 3N,

50/60

400 V, 3N,

50/60

230 V, 3,

50/60

400 V, 3N,

50/60

Net weight - kg.

250

250

250

250

250

250

    cooking chamber

34

34

34

34

34

34

    electric

34.5

34.5

34.5

34.5

34.5

34.5

    auxiliary

0.8

0.8

0.8

0.8

0.8

0.8

    boiler

24

20

24

24

20

24

Power - kW

    height

1450

1450

1450

1450

1450

1450

    depth

715

715

715

715

715

715

    width

460

460

460

460

460

460

Internal dimensions - mm

    height

1783

1783

1783

1783

1783

1783

    depth

845

845

845

845

845

845

    width

986

986

986

986

986

986

External dimensions - mm

N° of programs

100

100

100

Semi-automatic cleaning cycle

Meat probe

Multi Point Probe

Two-speed fan

Low temp steaming

Regeneration

Cook&hold

Humidity control

Convection/steaming

Steaming

Convection

    combi

250

250

250

250

250

250

    steam

100

100

100

100

100

100

    air-convection

300

300

300

300

300

300

Cooking cycles - °C

Runners pitch - mm

63

63

80

63

63

80

Shelf capacity

20

20

16

20

20

16

Type of grids

1/1

Gastronorm

1/1

Gastronorm

1/1

Gastronorm

1/1

Gastronorm

1/1

Gastronorm

1/1

Gastronorm

Functional level

Programmable;

Top

Programmable;

Top

Programmable;

Top

Medium

Medium

Medium

Power supply

Electric

Electric

Electric

Electric

Electric

Electric

TECHNICAL DATA

AOS201EAAQ

260606

AOS201EANQ

260616

AOS201EAHQ

260636

AOS201EBAQ

260607

AOS201EBNQ

260617

AOS201EBHQ

260637

• 

Air-o-clean (just for "version A” 

models): 4 different pre-set cycles to 
clean the cooking cell, according to 
the actual requirements. The cleaning 
system is built-in (no need for 
add-ons).

• 

Cell quick cooling: useful when 

passing to a type of cooking that 
requires a lower temperature than the 
previous one.

• 

Manual injection of water in the cell.

• 

Built-in retractable hand shower (for 

level B).

• 

Steam generator water draining 

with an automatic scale diagnosis 
system.

• 

HACCP management as standard: 

it allows recording the cooking 
programme according to H.A.C.C.P. 
standard (Hazard Analysis and Critical 
Control Points). According to the 
system requested it will be possible 
to record the cooking data with the 
oven’s printer (optional) or directly in 
a Personal Computer.

PERFORMANCE
• Air-o-clima [Patented] (just for 
"version A” models): controls and 
displays the exact (single degree of 
accuracy) humidity degree of the 
oven atmosphere in hot air, mixed 
and regeneration cycles. Air-o-clima 
measures physically the real humidity 
level inside the cooking cell and acts 
consequently according to the set 
value. With hot air cycles, air-o-clima 
also manages to exhaust the excess 
humidity generated from the food.

• 

Air-o-flow: blows fresh air from 

outside through the new fan, which 
pulls the air in from the backside of 
the oven, after it is pre-heated and 
therefore without compromising the 
evenness of the cooking process.
Multi-sensor food probe: 6 sensors, 
½ ºC accuracy.

CONSTRUCTION
• Stainless steel 304 throughout, with 
seamless joints in the cooking cell.

• 

Height adjustable legs.

• 

Double thermoglazed door with 

two-stage opening to let out the 
steam for maximum security and four 
holding positions allowing easier 
loading and unloading manoeuvres.

• 

Halogen lighting in the cooking cell.

• 

Access to main components from 

the front panel.

• 

Platinum probe in the boiler to 

detect the presence of scale build-up.

• 

IPX5 water protection.

• 

Air-o-steam ovens meet and VDE 

safety requirements.Installation 
diagram:
D = overflow drain pipe
U = air intake
P = fumes outlet
N= cooling water inlet.