21
3. Fix the hood and oven to the previously
assembled support (ref. F.3.1) using the
screws and toothed washers supplied, to
ensure mechanical fastening and the
equipotential connection
.
F.6 Air duct connection
The following items are arranged for the
connection of a 300x300 (118.11 x 118.11 inches)
duct:
To install the ducts refer to the “Hood Installation
Diagram” (pages 2) and chapter E.2.1 (page15).
F.7 Water drain connection
The hood is supplied with a drain pipe DWO;
connect it to the main drainage system or to a
floor grate.
F.8 Electrical connection
IMPORTANT
The connection to the electrical
power supply must be in
compliance with the current
national and local regulations.
F.8.1 Power cable
Before connecting, make sure the voltage and
frequency match that given on the data plate.
•
Connect the appliance to the power supply in a
permanent way with an H07 RN-F type cable
(
NOT PROVIDED
);
•
Install the power cable in a metal or rigid
plastic pipe without any sharp parts;
•
Install ahead of the appliance an omnipolar
switch of suitable capacity with contact gap of
at least 3 mm. Install the switch in the
building's electrical system, in the immediate
vicinity of the appliance;
•
If required by local standards and regulations,
a RCBO circuit breaker with Idn 300mA class
A must be provided in the power supply circuit
by the installer;
•
Appliance max. leakage current is 0.75 mA;
922728