Anomaly

Description

Instructions to User

12:1

Machine indicates that Inlet air over heat protection  

has cut out

Switch off power to the machine and contact authorized service

12:2

Machine indicates that Outlet air over heat protection 

has cut out

Push the control knob to restart the program

12:8  

(for condense  

models)

Machine indicates that condense water tank has  

not been drained within set time

1. Turn the machine off and on again. Condensate pump will start

2.  If water is coming out of the condensate drain hose, it might be 

partly blocked. Contact authorized service

3.  If the pump is running and no water coming out the drain is 

blocked. Contact authorized service

12:11 (for models  

with RMC system)

Machine indicates garment is not dry within max drying 

time (RMC)

1. Check that the dryer is not overloaded

2. Open the door to reset the error message

12:12 (for models 

with RMC)

Machine indicates garment is not dry within max drying 

time (AUTOSTOP)

1. Check that the dryer is not overloaded

2. Check that the garments are not loaded too wet after extraction)

3. Open the door to reset the error message

12:13 (for models 

with RMC)

Machine indicates garment is not dry within max drying 

time (TIME)

Open the door to reset error message

12:14  

(for gas models)

Machine indicates flame sensor is not detecting gas 

flame within set time

Reset the error message by a short push on the control knob 

Check the gas supply

12:15

Machine indicates vacuum switch is not activated  

within set time

Check that machine is not overloaded

Check that Doors are closed and seals are in good order

Press the control knob to clear error message and restart program

12:18

Machine indicates vacuum switch has deactivated  

several times during program run

Redistribute the load in the drum

Press control knob to clear message and restart the program

12:19 (Heat Pump 

models)

Machine indicates blocked air flow in heat pump unit

Clean lint filter

Press control knob to clear message and restart the program

12:253

Machine indicates that Jumper 1 is missing

Press control knob to clear message and restart the program

17:20 (Heat Pump 

models)

Machine indicates critical error in heat pump unit

Switch off power to the machine for 5 minutes and then on again

Try to start a new program

17:21 (Heat Pump 

models)

Machine indicates internal error in heat pump unit

Switch off power to the machine for 5 minutes and then on again

Try to start a new program after HP initializing has finished

20:1

Machine indicates drum motor is overheated

Wait 30 minutes to allow the motor to cool down

Press the control knob to clear error message

30:1

Machine indicates fan motor overheated

Wait 30 minutes to allow the motor to cool down

Press the control knob to clear error message