24
Problem
Cause
Correction
10. Low (or no) ice production.
11. Poor ice quality (soft or unclear
cubes)
Cause
12. Unit not freezing (compressor
and fan operating)
Cause
Cause
a. Dirty condensing coil (Control
board light shows rapid flash).
b. Stalled condenser fan blade
(Control board light shows a rapid
flash).
c. No water in water trough.
d. Bypass valve stuck in open
position.
e. Ice forms on a portion of
evaporator grid.
a. Poor incoming water quality.
b. Deposit build-up on evaporator
grid.
c. Water splashing on cubes.
a. Little or no cooling.
b. Bypass valve stuck in open
position.
Cause
a. Clean condensing coil.
b. Free up the blade or replace fan
motor.
c. Install stand pipe securely in
trough.
d. Replace bypass valve.
e. Check unit for system under
charge or leak.
a. Consult a plumber.
b. Run the unit through a clean
cycle. Use only Electrolux Ice
Machine Cleaner.
c. Adjust water flow above
evaporator.
Remedy
a. Check sealed system for leak or
restriction.
NOTE: See chart of suction
pressures in manual.
b. Replace bypass valve.
Remedy
NOTE: See chart of suction
pressures in manual.