HOMEOWNERS MANUAL & DEALER INSTALLATION  
INSTRUCTIONS

FOR MODELS 350 & 675

Rules for Safe Installation and Operation

READ AND SAVE THESE INSTRUCTIONS!
Please read instructions before installing and using the HEPA Central Air 
Filtration System (HEPA system). This will help you obtain the full benefit of 
the HEPA system you have selected. It will also help you to avoid needless 
service costs.
. Read this manual carefully. Failure to follow these rules and instructions 

could cause a malfunction of the air filter or unsatisfactory service and 
could void your warranty.

2. Follow a regular service and maintenance schedule to ensure efficient 

operation.

3. For safety and optimized performance of your HEPA system, all  

installation and maintenance must be performed by a professional heating 
and ventilation contractor. The installer should be made aware of your 
indoor air quality situation and be familiar with your heating, ventilation and 
air conditioning equipment.

4. High particulate distribution may occur during initial start-up of this product 

after installation or after scheduled filter changes. Individuals who are 
highly sensitive to airborne particulates should not be in the building and 
allow 24 hours of operation for removal of particulates from occupied 
spaces before re-entry.

Shipping and Packing List

Package  of  contains:
 - HEPA System
 - Complete Filter Set (Packed inside Unit)
 - Installation Kit
 - Installation Instructions (this manual)
 - Registration Card
 - Warranty Statement

HEPA System Models
Model 350 is designed to filter air up to a rate of 350 cfm. 
Model 675 is designed to filter air up to a rate of 675 cfm.

Table of Contents

Rules for Safe Installation and Operation ......................................................
Shipping and Packing List ...........................................................................
Introduction .................................................................................................2
General Information .....................................................................................2
Product Application Guidelines ....................................................................2
Parts Identification .......................................................................................3
Physical Dimensions of Units .......................................................................3
Dealer Installation Instructions .................................................................. 4-6
Operation ....................................................................................................6
Maintenance ................................................................................................7
Filter Change Schedule ................................................................................7
Filter Changing Guidelines ...........................................................................7
Dealer Filter Change Instructions .................................................................8
Dealer Motor Assembly Replacement Instructions .......................................9
Electrical Diagram ........................................................................................9
Beam Central HEPA Air FIltration Systems Item List ...................................0
Part Inventory ............................................................................................

Risk of property damage, injury or death.

Installation, adjustments, alterations, service and maintenance must be  
performed by a qualified technician.

Risk of Carbon Monoxide Poisoning.

Can cause injury or death. Do not operate equipment without access  
panel in place. Operation of this equipment without all access panels  
in place may cause gas fumes from the heating system to be drawn  
into occupied spaces.

Summary of Contents for 350 STEAMER HAND GUN

Page 1: ... particulates should not be in the building and allow 24 hours of operation for removal of particulates from occupied spaces before re entry Shipping and Packing List Package 1 of 1 contains 1 HEPA System 1 Complete Filter Set Packed inside Unit 1 Installation Kit 1 Installation Instructions this manual 1 Registration Card 1 Warranty Statement HEPA System Models Model 350 is designed to filter air...

Page 2: ...If air passes through the carbon filter before particulates are removed the surface of the carbon quickly gets covered with particulates rendering it ineffective at capturing chemicals and odors If particulates are removed from the air with a HEPA filter virtually the entire surface area of the carbon can be used to capture chemicals and odors This increases the efficiency and filter life of the c...

Page 3: ...A Cartridge Parts Inside Cabinet Filter Section Motor Impeller Filter Adapter threaded O Ring Parts Identification Filter parts identification Physical dimensions of unit E G C F A A A Filter Section Access Panel Air Intake Air Outflow Motor Section Access Panel B B D Model Unit A B C D E F G 350 14 5 36 8 27 25 692 7 875 200 5 875 149 8 5 216 3 76 2 51 675 14 5 368 27 25 692 9 875 251 7 875 200 6...

Page 4: ... space Ducting If HEPA system is installed where inlet and outflow collars face down metal elbows must be connected to both inlet and outflow collars Each connection must be sealed with aluminum tape or mastic including all take offs Installed duct runs should be as straight as possible if the duct runs are too long reduced CFM may result If duct is exposed to unconditioned air externally insulate...

Page 5: ...air outflow of the HRV ERV should be Y connected to the additional return duct then connected to the inlet of the HEPA system The additional return duct if any should be installed at least 6 ft away from the outflow duct on the main return Duct both the HRV ERV and the additional return into the intake of the HEPA system Outflow Marked as Clean Air Out on unit Outflow duct should be installed as c...

Page 6: ...ould be as straight as possible if the duct runs are too long reduced CFM may result If duct is exposed to unconditioned air insulated flex duct is highly recommended Example of Single Room Stand Alone System Installation For single rooms where increased filtration is desired such as a dedicated smoking room Externally insulated flex duct can also be used for noise reduction purposes For best indo...

Page 7: ... pre filter over time The color of the filter will change as particulates build up on the pre filter Change the pre filter when you can see the particulate build up start to clog up the pre filter HEPA Filter As the HEPA filter captures particulates it will darken over time Replace the HEPA filter when it darkens to the level seen in example D Inner Carbon Filter The inner carbon filter will rarel...

Page 8: ...rom the new inner carbon filter e Unroll the inner carbon filter and roll it up in the opposite direction this makes the filter follow a more contoured profile against the inner HEPA filter surfaces and helps keep it in place place the rolled inner carbon filter inside the HEPA cartridge and gently unroll it until the ends butt together and the filter is snug against the HEPA filter 4 HEPA Filter ...

Page 9: ...c c Connect the wires as follows Black wire from the Plug and Cable P12 to Line P3 on the CM71 Power Module Green wire from CM71 Power Module to the ground post Blue wire from motor to the Motor 2 P4 post on the CM71 Power Module Yellow green wire from motor to the ground post Brown wire from the motor to a Capacitor C10 post Black wire from the motor to the Motor 1 P2 post on the CM71 Power Modul...

Page 10: ...ke Collar 350 8 Exhaust Collar 350 6 Electronic Key Pad Electronic Switch Board Capacitor 350 O Ring Beam Model 675 Central HEPA Air Filtration System Replacement Filters HEPA Cartridge Replacement 15 Replacement HEPA for 350 675 Annual Filter Kit 15 Standard 1 Foam Prefilter 2 Carbon Inner Blanket for 350 675 Replacement Components For Beam Model 675 Central HEPA Air Filtration Systems Filter Cab...

Page 11: ...2 Bulk Head Model 350 172004 Model 675 172005 Motor Blower Model 350 172009 Model 675 172010 Motor Mount Model 350 172007 Model 675 172008 Base same for all models 172006 Cabinet Model 350 172002 Model 675 172003 Electronic Switch same for all models Key Pad 172014 Switch Board 172015 Capacitor Model 350 172016 Model 675 172017 Intake Collar Model 350 8 172012 Model 675 10 172011 Beam Central HEPA...

Page 12: ...12 Electrolux Central Vacuum Systems 1700 W Second Webster City IA USA 50595 visit our website at www beam com ...

Reviews: