background image

5

36" GAS RANGE INSTALLATION INSTRUCTIONS

 Do not use a flame to check for leaks

from gas connections. Checking for leaks with a flame
may result in a fire or explosion.

All openings in the wall or floor where the range is to be
installed must be sealed.

Tighten all connections

 if necessary to prevent gas

leakage in the cooktop or supply line.

Disconnect this range and its individual shutoff
valve

 from the gas supply piping system during any

pressure testing of the system at test pressures greater
than 1/2 psig (3.5 kPa or 14"(35,56 cm) water column).

Isolate the range from the gas supply piping system

by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5 kPa or
14"(35,56 cm) water column).

4.

 

Moving the Appliance for

Servicing and Cleaning

Turn off the range line fuse or circuit breakers at the main
power source, and turn off the manual gas shut-off valve.
Make sure the range is cold. Open the oven door. Lift the
range at the front and slide it out of the cut-out opening
without creating undue strain on the flexible gas conduit.
Make sure not to pinch the flexible gas conduit at the back
of the range when replacing the unit into the cut-out
opening. Close the door and switch on the electrical power
and gas to the range.

5.

 

Range Placement

 To eliminate the risk of burns or fire from

reaching over heated surface units, cabinet storage
space located above the range should be avoided. If
cabinet storage space is to be provided, the risk can be
reduced by installing a range hood that projects
horizontally a minimum of 5" (12.7 cm) beyond the
bottom of the cabinet.

Figure 5

Follow instructions for

the type of installation you have

Center

Line of

Range

If range will be installed with a cabinet on both
sides,

 draw a center line on the floor between the

cabinets (see figure 5). 

If back of range will not be

flush with the wall

 (the location of the outlet may not

allow the range to be positioned against the wall), draw
a line on the floor where the back edge of the range will
be. Now install anti-tip bracket (see "Anti-Tip Bracket
Installation", page 8).

If range will be installed with a cabinet on one side
only,

 move the range into final position. Draw a line on

the floor along the side of the range that is not against
the cabinet. 

If back of range will not be flush with

the wall

 (the location of the outlet may not allow the

range to be positioned against the wall), draw a line on
the floor where the back edge of the range will be. Now
install anti-tip bracket (see "Anti-Tip Bracket
Installation", page 8).

If range will not be installed against a cabinet,

move range into final position. Draw a line on the floor
along both sides of the range. 

If back of range will not

be flush with the wall

 (the location of the outlet may

not allow the range to be positioned against the wall),
draw a line on the floor where the back edge of the
range will be. Now install anti-tip bracket (see "Anti-Tip
Bracket Installation", page 8).

Summary of Contents for 318201778

Page 1: ...TRUCTIONS FOR FUTURE REFERENCE OBSERVE ALL GOVERNING CODES AND ORDINANCES Note For appliances installed in the state of Massachusetts see page 2 Refer to your serial plate for applicable agency certification NOTE 28 71 1 cm minimum clearance between the cooktop and the bottom of the cabinet when the bottom of wood or metal cabinet is protected by not less than 1 4 0 64 cm flame retardant millboard...

Page 2: ...unattended Stepping leaning or sitting on the door of this range can result in serious injuries and can also cause damage to the range Do not store items of interest to children in the cabinets above the range Children could be seriously burned climbing on the range to reach items To eliminate the need to reach over the surface units cabinet storage space above the units should be avoided Adjust s...

Page 3: ...ve or bypass the grounding prong Power supply cord with 3 prong grounding plug Figure 2 2 Electrical Requirements 120 volt 60 Hertz properly grounded dedicated circuit protected by a 15 amp circuit breaker or time delay fuse Note This range is not recommended to be installed with a Ground Fault Interrupt GFI Do not use an extension cord with this range Grounding Instructions IMPORTANT Please read ...

Page 4: ...ak and possible fire or explosion The gas supply line to the shutoff valve should be 1 2 1 27 cm or 3 4 1 9 cm solid pipe The user must know the location of the main shutoff valve and have easy access to it When using flexible gas conduit on the range allow sufficient slack to pull the range outside the cutout for cleaning or servicing NOTE Do not allow the flexible conduit to get pinched between ...

Page 5: ...er heated surface units cabinet storage space located above the range should be avoided If cabinet storage space is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinet Figure 5 Follow instructions for the type of installation you have Center Line of Range If range will be installed with a cabinet on bo...

Page 6: ...normal operation after air has been purged from supply lines Visually check that burner has lit c Once the burner lights the control knob should be rotated out of the LITE position There are separate ignition devices for each burner Try each knob separately until all burner valves have been checked Regular Burner Burner Cap Fixed Burner Ring and Burner Base Dual Surface Burner Burner Base Fixed Bu...

Page 7: ...igure 8 4 Adjust the LOW Setting of Regular Burner see figure 7 on the Surface Burner Valves Figure 8 a Push in and turn control to LITE until burner ignites b Quickly turn knob to LOWEST POSITION c If burner goes out reset control to OFF d Remove the surface burner control knob and decorative ring e Insert a thin bladed screwdriver into the hollow valve stem and engage the slotted screw inside Fl...

Page 8: ...anti tip brackets are engaged Important Safety Warning To reduce the risk of tipping of the range the range must be secured to the floor by the properly installed anti tip bracket and screws packed with the range These parts are located in a plastic bag in the oven This gas range has two brackets Failure to install the bracket will allow the range to tip over if excessive weight is placed on an op...

Page 9: ...la agencia de servicio o el proveedor de gas Nota Para electrodomésticos instalados en el estado de Massachussets Vea página 12 P N 318201778 0809 Rev A English pages 1 8 Español páginas 9 16 Notas páginas 17 19 Diagrama de la instalación alámbrica página 20 G F 13 Max 33 cm Max 35 7 8 Mín 91 1 cm Mín PARED PARED 18 Mín 45 7 cm Mín A B C D E NOTA Un espacio mínimo de 28 71 1 cm entre la superficie...

Page 10: ...ard for Mobil Home Construction and Safety título 24 HUD parte 280 o cuando tal estándar no se aplica el Standard for Manufactured Home Installation 1982 Manufactured Home sites Communities and Setups ANSI Z225 1 NFPA 501A edición más reciente o con los códigos locales Esta estufa ha sido diseñada y certificada por el organismo CSA Internacional Como en cualquier electrodoméstico donde se use gas ...

Page 11: ...ufe de pared con toma de tierra Figura 2 2 Requisitos eléctricos 120 voltio 60 Hertzio circuito dedicado apropiadamente puestos a tierra protegido por un circuito de amperio o fusible de demora de tiempo de 15 amp Nota no es recomendado instalarlo con un Interruptor GFI de puesta a tierra No utilice una extensión con esta estufa Instrucciones de puesta a tierra IMPORTANTE Por favor lea con cuidado...

Page 12: ...onector codo de 90o Monte el conector flexible desde el tubo de suministro de gas hasta el conector T de gas según este orden 1 Válvula de cierre manual no incluido 2 Conector flexible no incluido 3 Conector codo de 90o no incluido 4 Conector T de gas incluido Conector T de gas Conexión del regulador El regulador esta instalado en el electrodoméstico Asegurese de no apretar demasiado la conexión E...

Page 13: ...nter Line of Range Si la estufa se va a instalar con armarios laterales marque el centro de la abertura del armario en el piso ver la figura 5 Si la parte trasera de la estufa no estará a ras con la pared la ubicación del tomacorriente puede que no permita que la estufa se pegue a ras con la pared marque el piso donde estará el border trasero de la estufa Ponga el patrón en el piso alineando la lí...

Page 14: ...sición LITE Cada quemador tiene su encendedor individual Controle las perillas separadamente hasta que todas las válvulas hayan sido controladas 4 Ajuste bajo LO para la válvula de los quemadores de superficie estandar Figuras 7 y 8 a Presione y gire el control hasta la posición LITE para prender los quemadores 6 Instalación de la estufa 1 La parte trasera de la estufa puede ser directamente insta...

Page 15: ... a la POSICIÓN MÁS BAJA c Si el quemador se apaga reajuste el control a OFF d Retire la perilla del quemador de superficie Figura 9 e El tamaño de la flama de la porción posterior del quemador puente puede aumentarse o disminuirse dándole vuelta al tornillo A vea Figura 9 Utilice el tornillo B para ajustar el tamaño de la llama de la porción central del quemador puente o del quemador triple Dé vue...

Page 16: ...este instalada utilice el diagrama en el cuadro 10 para situar el soporte si la plantilla no está disponible 4 Marque en el piso la localización de los agujeros de montaje demostrados en la plantilla posición derecha y izquierda Para una instalación más fácil los agujeros 1 2 1 3 centímetros de diámetro y 3 16 4 8 milímetros de profundidad pueden perforarse en el piso 5 Quite la plantilla y coloqu...

Page 17: ...17 NOTES NOTAS ...

Page 18: ...18 NOTES NOTAS ...

Page 19: ...19 NOTES NOTAS ...

Page 20: ...WIRING DIAGRAM DIAGRAMA DE LA INSTALACIÓN ALÁMBRICA 20 ...