Important safety Instructions

READ AND SAVE THESE INSTRUCTIONS

Automatically Operated Device - To Reduce 

The

Risk Of Injury Disconnect From Power Supply Before
Servicing.

This unit is equpeed with integral disconnecting switch
located inside the blower housing

TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE.
a)   Never leave surface units unattended at high settings.

Boilovers cause smoking and greasy spillovers that may
ignite.  Heat oils slowly on low or medium settings.

b) Always turn hood ON when cooking at high heat or

when flambeing food (I.e. Crepes Suzette, Cherries
Jubilee, Peppercorn Beef Flambe’).

c) Clean ventilating fans frequently.  Grease should not

be allowed to accumulate on fan or filter.

d) Use proper pan size.  Always use cookware appropri-

ate for the size of the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS, IN
THE EVENT OF A RANGE TOP GREASE FIRE, OB-
SERVE THE FOLLOWING
:
a) SMOTHER FLAMES with a close-fitting lid, cookie

sheet, or other metal tray, then turn off the gas burner
or the electric element.  BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.

b) NEVER PICK UP A FLAMING PAN - you may be

burned.

c) DO NOT USE WATER, including wet dishcloths or tow-

els - a violent steam explosion will result.

d) Use an extinguisher ONLY if:

1) You know you have a class ABC extinguisher, and

you already know how to operate it.

2) The fire is small and contained in the area where it

started.

3) The fire department is being called.
4) You can fight the fire with your back to an exit.

OPERATION

a. Always leave safety grills and filters in place. Without
these components, operating blowers could catch onto hair,
fingers and loose clothing.

The manufacturer declines all responsibility in the event
of failure to observe the instructions given here for instal-
lation, maintenance and suitable use of the product. The
manufacturer further declines all responsibility for injury
due to negligence and the warranty of the unit automati-
cally expires due to improper maintenance.

Important safety Instructions

FOR GENERAL VENTILATING USE ONLY.  DO NOT USE
TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERI-
ALS OR VAPORS.

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,

OR INJURY TO PERSONS, OBSERVE THE FOL-
LOWING:

A. Use this unit only in the manner intended by the manu-

facturer.  If you have questions, contact the manufac-
turer.

B. Before servicing or cleaning the unit, switch power off

at service panel and lock service panel disconnecting
means to prevent power from being switched on acci-
dentally.  When the service disconnecting means can-
not be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.

C. Installation Work and Electrical Wiring Must Be Done

By Qualified Person(s) In Accordance With All  Appli-
cable Codes & Standards, Including Fire-rated Con-
struction.

D. Sufficient air is needed for proper combustion and ex-

hausting of gases through the flue (Chimney) of fuel
burning equipment to prevent back- drafting.  Follow
the heating equipment manufacturers guideline and
safety standards such as those published by the Na-
tional Fire Protection Association (NFPA), the Ameri-
can Society for Heating, Refrigeration and Air Condi-
tioning Engineers (ASHRAE), and the local code au-
thorities.

E. When cutting or drilling into wall or ceiling, do not dam-

age electrical wiring and other hidden utilities.

F. Ducted systems must always be vented to the outdoors.

To reduce risk of fire and to properly exhaust air, be
sure to duct air outside - do not vent exhaust air into
spaces within walls, ceilings, attics, crawl spaces, or
garages.

TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCT WORK.
Install this hood in accordance with all requirements speci-
fied.

To Reduce The Risk Of  Fire Or  Electric Shock, Do Not
Use This Hood With Any External Solid State Speed
Control Device.

Summary of Contents for 316488522

Page 1: ...Use Care Guide 30 and 36 Free Standing Range Hood Guia de Instalación Uso y Cuidado 30 y 36 Campana extractora Guide d installation utilisation et d entretien 30 et 36 Hotte aspirante EI30WC60GS EI36WC60GS 316488522 ...

Page 2: ...ements ements ements ements 5 5 5 5 5 Electrical requirements 5 IMPORTANT 5 Before installing the hood 5 List of Materials List of Materials List of Materials List of Materials List of Materials 6 6 6 6 6 Parts Included with your Hood 6 Optional Accessories 6 Tools Materials required 6 Installing the hood Installing the hood Installing the hood Installing the hood Installing the hood 7 14 7 14 7 1...

Page 3: ... For r For r For residential use only esidential use only esidential use only esidential use only esidential use only Do not attempt to install or operate your appliance until you have read the safety precautions in this manual Safety items throughout this manual are labeled with a WARNING or CAUTION based on the risk type This symbol alerts you to situations that may cause serious body harm death...

Page 4: ...or instal lation maintenance and suitable use of the product The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automati cally expires due to improper maintenance Important safety Instructions FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERI ALS OR VAPORS TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJ...

Page 5: ...NFPA 70 latest edi tion or CSA Standards C22 1 94 Canadian Electri cal Code Part 1 and C22 2 No 0 M91 latest edi tion and all local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Q...

Page 6: ...attachment anchors screws 6 pieces 1 8 x 3 8 Assembly screws 8 pieces Optional accessories Optional accessories Optional accessories Optional accessories Optional accessories Re circulation KIT Charcoal filter T T T T Tools Materials r ools Materials r ools Materials r ools Materials r ools Materials requir equir equir equir equired ed ed ed ed Duct tape Wire nuts Tape to mount template 8 rounded ...

Page 7: ... installed for recirculating operation recirculating accessories not supplied with the hood This hood can be installed over any electric and gas cooktop range It can not be installed over any pr It can not be installed over any pr It can not be installed over any pr It can not be installed over any pr It can not be installed over any professional ofessional ofessional ofessional ofessional cooktop...

Page 8: ... do not crush when making corners Ductwork and wiring locations Ductwork and wiring locations Ductwork and wiring locations Ductwork and wiring locations Ductwork and wiring locations Determine the exact location of the vent hood Locate the template packed with the literature The height installation is determined by the following image Mark the location Installation height Installation height 30 g...

Page 9: ... ducting Ceiling ducting Ceiling ducting If the duct will vent straight up to the ceiling Use level to draw a line straight up from the centerline on the template to the ceiling Measure at least 4 12 16 from the back wall to the circle center of an 8 hole on the ceiling W W W W Wall ducting all ducting all ducting all ducting all ducting If ductwork will vent to rear Use a level to draw a line str...

Page 10: ...ng must be capable of Framing must be capable of Framing must be capable of supporting 100 lbs supporting 100 lbs supporting 100 lbs supporting 100 lbs supporting 100 lbs 1 x6 Min Mounting Support Centerline of Installation Space View From Rear Cleats 8 1 2 min opening for ductwork Mounting the hood Mounting the hood Mounting the hood Mounting the hood Mounting the hood W W W W WARNING ARNING ARNI...

Page 11: ...e the hood Drive lower wood screws by hand Remove screws Mount the hood onto the upper screws Drive and tighten the upper wood screws by hand Drive and tighten the lower wood screws by hand Install the plastic gasket to the front hood flange ...

Page 12: ...allation Air deflector installation Air deflector installation Recir Recir Recir Recir Recirculating accessories culating accessories culating accessories culating accessories culating accessories Assemble the air deflector with the duct cover bracket with 4 assembly screws provided as shown Measure from the bottom of the air deflector to the bottom of the hood outlet as shown Dimension to measure...

Page 13: ... result in death or electrical esult in death or electrical esult in death or electrical esult in death or electrical esult in death or electrical shock shock shock shock shock Remove junction box cover and knockout on the top left side Knockout Junction box cover If not already done install 1 2 conduit connector in j box Metal electrical conduit U L listed wire nut House wiring Run black live whi...

Page 14: ...er part of the telescopic duct cover pull it and place it in the duct cover mounting bracket Secure the top of the duct with 2 assembly screws provided Secure the bottom of the duct with 2 assembly screws provided Install the grease filter and turn power on at service panel Check operation of the hood IMPORTANT If the hood doesn t switch ON before calling for service check if the internal General ...

Page 15: ...1 1 1 Blower and light controls 2 2 2 2 2 Lamp housings 3 3 3 3 3 Grease filter Handle 4 4 4 4 4 Grease filter 5 5 5 5 5 Canopy 6 6 6 6 6 Duct cover 7 7 7 7 7 Louver holes Only for Recirculating version 1 4 3 5 6 7 2 2 2 Features ...

Page 16: ...ngs 4 4 4 4 4 Button Speed Decr Button Speed Decr Button Speed Decr Button Speed Decr Button Speed Decrease OFF ease OFF ease OFF ease OFF ease OFF This button is used to decrease the fan speed or turn OFF the fan The fan will turn OFF if the button is pressed and the hood was in the first speed If the fan is at second speed and the button is pressed the fan will be set to first speed If the fan i...

Page 17: ...es on display the charcoal filters installed are required to be replaced or reactivated To reset the charcoal filter saturation indication the user must press the button for 5 seconds after this time the icon Char Char Char Char Charcoal filter coal filter coal filter coal filter coal filter is not displayed and the hood has the normal display operation Audible signal activation and deactivation A...

Page 18: ...lish air currents upward through the hood Thus when heat smoke moisture grease and cooking odors are produced they will be carried outside instead of drifting into other rooms Use the low speeds for normal use and the higher speeds for strong odors or fumes Drafts across the range or cooktop will cause the escape of heat smoke moisture grease and cooking odors from the hood Such drafts should be p...

Page 19: ...t power from being switched on accidentally NOTE T NOTE T NOTE T NOTE T NOTE Tur ur ur ur urn of n of n of n of n off the lights and fan Allow the lights f the lights and fan Allow the lights f the lights and fan Allow the lights f the lights and fan Allow the lights f the lights and fan Allow the lights to to to to to cool cool cool cool cool befor befor befor befor before handling e handling e h...

Page 20: ...ess steel for extended periods Plastic surfaces Plastic surfaces Plastic surfaces Plastic surfaces Plastic surfaces Wipe with a moist soapy sponge Rinse and dry Aluminum Mesh Filters Clean filters in the dish washer or by agitating in sudsy water Ensure that there is no soil trapped in the fine mesh Dry the filters before reinstalling them Anodized Aluminum surfaces Anodized Aluminum surfaces Anod...

Page 21: ...onnections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent tubes on models with these features This warranty does not cover the following This warranty ...

Reviews: