16
User manual
Every 6 Months or 1000 hours (Refer this service to qualified personnel)
Caution
To be carried out by qualified personnel.
• Inspect and remove lint accumulation external exhaust ductwork and from dryer’s internal exhaust ducting.
• The accumulation of lint in the exhaust ductwork can create a potential fire hazard.
• Do not obstruct the flow of combustion and ventilation air. Check back draft dampers in the exhaust ductwork. In-
spect and remove any lint accumulation, which can cause the damper to bind or stick. Obstructed ducting leads to
longer drying times, higher energy consumption and reduced motor life.
• If ducting is highly obstructed with lint change to a shorter service interval such as every three months.
• A back-draft damper that is sticking partially closed can result in slow drying and the shutdown of heat circuit
safety switches or thermostats.
• When cleaning the dryer cabinet, avoid using cleaners with harsh abrasives. A product intended for appliance
cleaning is recommended.
Every 12 Months or 2000 hours
Caution
To be carried out by qualified personnel.
• A competent service professional should inspect bolts, nuts, screws, setscrews, grounding.
• Belts should be examined. Cracked or seriously frayed belts should be replaced.
• Complete an operational check of controls and valves.
• Complete an operational check of all safety devices (lint switch, door switch).
Summary of Contents for TE1220E
Page 1: ...User manual Tumble dryer TE1220E TE1220G Original instructions 0180500988 EN 2021 09 27 ...
Page 2: ......
Page 4: ......
Page 18: ......
Page 19: ......
Page 20: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...