User manual
7
1.1
Additional safety precautions for gas heated tumble dryer
• Before installation, check that the local distribution conditions, nature of gas and pres-
sure and the adjustment of the appliance are compatible.
• The machine is not to be installed in rooms containing cleaning machines with per-
chloroethylene, TRICHLOROETHYLENE or CHLOROFLUOROCONTAINING HY-
DROCARBONS as cleaning agents.
• NOTE: it is pointed out that the connection and commissioning of appliances complying
with this standard are subject to observance of the installation regulations in force in
the countries where these appliances are marketed.
• Connection to the appliance shall be made with a flexible hose suitable for the appli-
ance category in accordance with national installation regulations of the country of des-
tination and that in case of doubt the installer shall contact the supplier.
• The appliance should be installed on non-flammable materials for the floor, worktop
and/or wall close to the appliance if required.
• If you can smell gas:
– Do not switch on any equipment
– Do not use electrical switches
– Do not use telephones in the building
– Evacuate the room, building or area
– Contact the person responsible for the machine
1.2
General information
Conditions for storage and transportation of the appliance should fulfil a temperature between -20
℃
/ + 70
℃
and
max Humidity of 95% RH.
In order to prevent damage to the electronics (and other parts) that may occur as the result of condensation, the ma-
chine should be placed in room temperature for 24 hours before being used for the first time.
Electric power supply should follow:
• Max range for each country rated voltage: -15% / +10%.
• Max range for each country rated frequency: ± 3 Hz.
• Dips/Interruption: 5 Dips/day (100% voltage lost, with 3-4 minutes duration).
A stable power supply is always the best. Fluctuations gives stress and additional load on all electric and electronic
components.
1.3
Commercial use only
The machine/machines covered by this manual is/are made for commercial and industrial use only.
1.4
Ergonomics certification
The human body is designed for movement and activity but physical stress injuries as a result of static and repetitive
movements or unfavorable working postures may occur.
The ergonomic features of your product, the ones which may influence your physical and cognitive interaction with it,
have been assessed and certified.
A product which exhibits ergonomic features, in fact, shall fulfil specific ergonomic requirements, belonging to three
different areas: Polytechnic, Biomedical and Psychosocial (usability and satisfaction).
For each of these areas, specific tests with real users have been performed. The product was therefore compliant
with the ergonomic acceptability criteria requested by the standards.