1 Safety Precautions

• Servicing shall be carried out only by authorized personnel.
• Only authorized spare parts, accessories and consumables shall be used.
• The machine is not to be used if industrial chemicals have been used for cleaning.
• Do not dry unwashed items in the machine.
• Items that have been soiled with substances such as cooking oil, acetone, alcohol, pet-

rol, kerosene, spot removers, turpentine, waxes and wax removers should be washed
in hot water with an extra amount of detergent before being dried in the machine.

• Items such as foam rubber (latex foam), shower caps, waterproof textiles, rubber

backed articles and clothes or pillows fitted with foam rubber pads should not be dried
in the machine.

• Fabric softeners or similar products should be used as specified by the fabric softener

instructions.

• The final part of a drying cycle occurs without heat (cool down cycle) to ensure that the

items are left at a temperature that ensures that the items will not be damaged.

• Remove all objects from pockets such as lighters and matches.
• WARNING. Never stop the machine before the end of the drying cycle unless all items

are quickly removed and spread out so that the heat is dissipated.

• Adequate ventilation has to be provided to avoid the back flow of gases into the room

for appliances burning other fuels, including open fires.

• Exhaust air must not be discharged into a flue which is used for exhausting fumes from

appliances burning gas or other fuels.

• The machine must not be installed behind a lockable door, a sliding door or a door with

a hinge on the opposite side to that of the machine in such a way that a full opening of
the machine is restricted.

• If the machine has a lint trap this has to be cleaned frequently.
• The lint must not be accumulated around the machine.
• DO NOT MODIFY THIS APPLIANCE.
• When performing service or replacing parts, the power must be disconnected.
• When the power is disconnected, the operator must see that the machine is discon-

nected (that the plug is removed and remains removed) from any point to which he has
access. If this is not possible, due to the construction or installation of the machine, a
disconnection with a locking system in the isolated position shall be provided.

• In accordance with the wiring rules: mount a multi-pole switch prior to the machine to

facilitate installation and service operations.

• WARNING: The appliance must not be supplied through an external switching device,

such as a timer, or connected to a circuit that is regularly switched on and off by a utility.

• If different rated voltages or different rated frequencies (separated by a /) are stated at

the machine data plate, instructions for adjusting the appliance for operation at the re-
quired rated voltage or rated frequency are stated in the installation manual.

• Stationary appliances not fitted with means for disconnection from the supply mains

having a contact separation in all poles that provide full disconnection under overvolt-
age category III, the instructions state that means for disconnection must be incorpo-
rated in the fixed wiring in accordance with the wiring rules.

• The openings in the base, shall not be obstructed by a carpet.

Summary of Contents for QuickDry QDC N1130 Series

Page 1: ...User manual Tumble dryer TD6 6 LAB Type N1130 Original instructions 438921540 EN 2022 09 01 ...

Page 2: ......

Page 3: ...tional functions 12 5 4 When program has ended 13 6 Error codes 14 7 Maintenance 15 7 1 General 15 7 2 Time for maintenance 15 7 3 Every day 15 7 4 Fresh air intake 16 7 5 Check the air flow 17 7 6 Machines with residual moisture control RMC 17 7 7 Maintenance to be carried out by qualified service personnel 17 8 Disposal information 18 8 1 Disposal of appliance at end of life 18 8 2 Disposal of p...

Page 4: ......

Page 5: ...not be installed behind a lockable door a sliding door or a door with a hinge on the opposite side to that of the machine in such a way that a full opening of the machine is restricted If the machine has a lint trap this has to be cleaned frequently The lint must not be accumulated around the machine DO NOT MODIFY THIS APPLIANCE When performing service or replacing parts the power must be disconne...

Page 6: ... reduced physical sensory or mental capabilities or lack of experience and knowl edge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the ap pliance Cleaning and user maintenance shall not be made by children without supervision Additional requirements for other countries This applianc...

Page 7: ...nd or other that does not comply with the technical requirements for each appliance plumbing parts components or consumable cleaning products that are not approved by the manufacturer customer s negligence misuse abuse and or non compliance with the use and care instructions detailed within the appropriate equipment documentation improper or poor installation repair maintenance including tampering...

Page 8: ...8 User manual 3 Operating panel A B fig X01076 A Display B Control knob ...

Page 9: ...selected The program will stop when the time is up LOW LAB Program fulfills reguirements for ISO 6330 2012 Max exhaust temperature 60 C Different drying times can be selected The program will stop when the time is up NO HEATING Airing bedspreads duvets and bedclothes Different drying times can be selected The program will stop when the time is up Automatic programs Description NORMAL EXTRA DRY Den...

Page 10: ...al 5 Handling 5 1 Load Note Remove all objects from pockets and make sure there are no metal objects such as screws pins etc left Metal objects might cause damage to the drum Make sure the filter is clean fig 7363 ...

Page 11: ...kg 5 2 How to start the machine Time programs Select program by turning the control knob Example of programs NORMAL LAB LOW LAB NO HEATING Start the machine by pressing the control knob After start it is possible to change the time for the selected program Turn the control knob to set the desired time ...

Page 12: ...not be available or active on your machine Stop function If the machine is programmed with this function it is possible to stop the machine during program run by pressing the control knob When pressing the control knob again the program will continue Pause It is possible to pause an ongoing program Select PAUSE and activate For some machines it is also possible to pause directly when pressing the ...

Page 13: ...he machine Statistics Select STATISTICS and activate The statistics menu shows total run hours and trip run hours for the machine 5 4 When program has ended Note For the best possible drying result it is important to empty the machine as soon as the program has ended If the machine is not emptied as soon as the program has ended the drum will rotate in short intervalls in order to keep the goods f...

Page 14: ... machine is overfilled or the garment is too wet 12 12 DRYING ERROR WITH AUTOSTOP PROGRAM The longest permitted automatic stop time has been exceeded Applies only to machines with automatic stop The machine is overfilled or the garment is too wet 12 18 REDISTRIBUTION OF LOAD NEEDED Machine indicates that load is blocking the airflow Redistribute the load Restart the machine to clear error message ...

Page 15: ...le a telephone number and or a tag will also be displayed The machine can be used meanwhile However the message will keep coming back until the service is performed The message will disappear after about 30 seconds or if the control knob or any button is pressed 7 3 Every day Check that the machine does not operate with the door or filter door open if so the machine must be placed out of order unt...

Page 16: ...any lint and dust around the machine 7 4 Fresh air intake At regular basis check that the fresh air intake on the front of the machine is not clogged by lint and dust or otherwise blocked Clean with a vacuum cleaner fig 7386 ...

Page 17: ...trol Peak inlet temperature should reach 120 125 C Continue to monitor for 10 15 min and if needed readjust air flow Lock air damper setting after adjustment A 5 x A 1 m fig W00197B 7 6 Machines with residual moisture control RMC At regular basis wipe off clean drum and lifters with citric acid Acidum citricum If soap softener residue remains it is recommended also to use a coarse sponge Lack of c...

Page 18: ...ed and that the refrigerator and heat pump components are special waste assimilable with urban waste The symbol on the product indicates that this product should not be treated as domestic waste but must be correctly disposed of in order to prevent any negative consequences for the environment and human health For further information on the recy cling of this product contact the local dealer or ag...

Page 19: ......

Page 20: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...