Installation manual
29
6.3
Three-phase connection
Demount the cover panel from the supply unit. Connect the earth and other wires as shown.
3AC
L3
L2
L1
N
3AC
L1
L2
L3
3NAC
L3
L2
L1
N
3NAC
N
L1
L2
L3
6.4
Electrical connections
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
machines
220–240V 1 ~
50/60
6.0
6.3
32
220–230V 3 ~
50/60
6.0
6.3
20
240V 3 ~
50/60
6.0
6.3
16
380–400V 3 ~
50/60
6.0
6.3
10
415/440/480V 3 ~
60
6.0
6.3
10
Gas heated
machines
220–480V 1/3 ~
50/60
*
0.3
10
Machines with heat
pump
220-240V 1/1N 3 ~
50/60
*
2.3
10
380-415V 3N ~
50/60
*
2.3
10
* Total power and recommended fuse does not depend on the heating power in those cases.