31
WH6–14
Electrical connections
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
220-240V 1/1N~
50/60
4.8/13.0
5.2/13.4
25/63
220-240V 3~
50/60
4.8/13.0
5.2/13.4
16/35
380-415V 3N/3~
50/60
4.8/13.0
5.2/13.4
10/20
440V 3~
50/60
13.0
13.4
20
480V 3~
60
13.0
13.4
20
Non heated/Steam
heated
208-240V 1/1N~
50/60
1
1.2
10
380-480V 1~
2
50/60
1.2
10
1.
Total power and recommended fuse does not depend on the heating power in those cases.
2.
Prepared for 3~
WH6–20
Electrical connections
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
220-240V 3~
50/60
18.0
18.5
50
380-415V 3N/3~
50/60
18.0
18.5
32
440V 3~
50/60
18.0
18.5
25
480V 3~
60
18.0
18.5
25
Non heated/Steam
heated
208-240V 1/1N~
50/60
1
2.5
10
380-480V 1~
2
50/60
2.5
10
1.
Total power and recommended fuse does not depend on the heating power in those cases.
2.
Prepared for 3~
WH6–27
Electrical connections
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
220-230V 3~
50/60
19.1
19.8
63
220-240V 3~
50/60
19.8/23.0
20.5/23.7
63/63
380-400V 3N/3~
50/60
19.1
19.8
32
380-415V 3N/3~
50/60
19.8/23.0
20.5/23.7
32/35
440V 3~
50/60
21.0/23.0
21.7/23.7
32/32
480V 3~
60
22.8/23.0
23.5/23.7
32/32
Non heated/Steam
heated
208-240V 1/1N~
50/60
1
2.6
16
380-480V 1~
2
50/60
2.6
10
1.
Total power and recommended fuse does not depend on the heating power in those cases.
2.
Prepared for 3~
WH6–33
Electrical connections
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
220-230V 3~
50/60
19.1
19.4
50
220-240V 3~
50/60
19.8/23.0
20.2/23.3
50/63
380-400V 3N/3~
50/60
19.1
19.6
32
380-415V 3N/3~
50/60
19.8/23.0
20.1/23.3
32/35
380V 3N~
50
9.5
9.9
16
440V 3~
50/60
21.0/23.0
21.4/23.3
32/32
480V 3~
60
22.8/23.0
23.2/23.4
32/32
Non heated/Steam
heated
208-240V 1/1N~
50/60
1
3.5
16
380-480V 1~
2
50/60
3.5
10
1.
Total power and recommended fuse does not depend on the heating power in those cases.
2.
Prepared for 3~
Summary of Contents for Compass Pro WH6-11
Page 2: ......
Page 4: ......
Page 46: ......
Page 47: ......