30
Installation manual
8.3
Three-phase connection
Demount the cover panel from the supply unit. Connect the earth and other wires as shown.
3AC
3AC
L1
L2
L3
3NAC
3NAC
L1
L2
L3 N
When the installation is completed remount the cover panel and check:
• That the drum is empty.
• That the machine operates by connecting the power to the machine and start a program with heat.
Summary of Contents for Compass Pro TD6-30LAC
Page 2: ......
Page 4: ......
Page 43: ......
Page 44: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...