Installation manual
31
8.3
Three-phase connection
Demount the cover panel from the supply unit. Connect the earth and other wires as shown.
3AC
L3
L2
L1
N
3AC
L1
L2
L3
3NAC
L3
L2
L1
N
3NAC
N
L1
L2
L3
When the installation is completed remount the cover panel and check:
• That the drum is empty.
• That the machine operates by connecting the power to the machine and start a program with heat.