23
ENGL
ISH
H
STARTING
H1
Preliminary checks, adjustments and
operational tests
H1.1
Electrical and plumbing checks
Before starting the machine:
•
check correct connection of the electrical wires that
feed the machine;
•
make sure the power supply voltage and frequency
match the data given in Table 1;
•
check correct connection of the water supply and
drain pipes (see par. F6 “Plumbing connections”);
•
make sure all the guards and safety devices are in
place and efficient.
H1.2
Check the positioning of tank components
H1.2.1
Check the fitting of filters
Make sure the filters "C" - "D" - "E" are correctly fitted
(Figure 15).
.
H1.2.2
Arm fitting check
Make sure the upper and lower wash and rinse arms
are correctly fitted (Figure 16).
H2
Starting
•
Open the water supply cocks.
•
Turn the main switch of the machine to “I”.Press the
On/Off key Table 2 (“A” - “Control panel”).
H3
Detergent/rinse-aid dispensers and
settings
The peristaltic dispensers (detergent and rinse aid)
and the tube inside the rinse aid dispenser require
periodical maintenance (at least once or twice a year)
or after prolonged periods of machine inactivity.
1. Dishwasher with incorporated detergent dis-
penser pump (Figure 17).
Pump “R” dispenses about 0.9 g/s of detergent. When
the appliance is filled with water for the first time in the
day, it dispenses about 46 g of detergent in 55 sec.,
thereby providing a concentration of 2 g/l. Pump “R”
dispenses about 4 g in 5 sec. at each cycle.
Dispenser operating time may be changed, following
the instructions given in the next paragraph (H4 Setting
the dispensers).
Insert the hose provided in the kit into the detergent
container.
2. Dishwashers with incorporated peristaltic
rinse-aid dispenser pump (Figure 17).
Pump “S” dispenses about 0.1 g/s of rinse-aid. When
the appliance is filled with water for the first time in the
day, it dispenses about 1,2 g in 11 sec., thereby provi-
ding a concentration of 0,1 g/l. Pump “S” dispenses
about 0,2 g in 2 sec. at each rinse cycle.
Dispenser operating time may be changed, following
the instructions given in the next paragraph (H4 Setting
the dispensers).
Insert the hose provided in the kit into the rinse-aid
container.
IMPORTANT!
These operations must only be carried
out by specialized technicians pro-
vided with adequate personal protec-
tion equipment (e.g. safety footwear,
gloves, glasses, etc.), tools and suita-
ble ancillary equipment.
IMPORTANT!
The following operations must be car-
ried out by operators provided with
suitable personal protection equipment
(e.g. protective gloves, etc.) with the
machine switched off and cold.
Figure 15 Tank filters
C
D
E
Figure 16 Wash and rinse arms
Summary of Contents for 506048