background image

6

7

SIGNAL

 indicates the presence 

of an input signal.

CLIP

 brief blinking indicates that the power 

amplifier is operated at its limits. Short-term 
blinking is uncritical, because the integrated 
limiter compensates minor distortion. Constant 
lighting of the LED indicates that the sound is 
negatively affected. Reducing the output volume 
is strongly recommended.

INPUT 

Electronically balanced input 
for the connection of high-
level signal sources like mixing 
consoles or signal processors. 
Connections can be established 
using phone or alternatively 
XLR-type connectors. 

Caution: Preventing the 
occurrence of spurious noise.
Prior to connecting/
disconnecting the input, 
set the level control to its 
counterclockwise stop.

 

OUTPUT 

This connector is connected in 
parallel to the input allowing the 
through connection of the input 
audio signal.

LEVEL

dB-scaled level control for 
adjusting the power amp’s 
overall amplification. To prevent 
distortion and clipping of pre-
linked mixing consoles, the 
control should generally be set 
to a value between 0dB and 
+6dB. 

MAINS IN

 

Mains connector is carried out 
as PowerCon-type socket. A 
fitting mains cord (5m) with 
PowerCon-type plug is supplied.

POWER

Mains switch for powering the appliance on or off. With 
the power amplifier being switched on, the mains switch 
is backlit. If, after switching the power on, the switch 
is not backlit, please first check whether the mains 
cord is correctly connected. In case the cord has been 
connected correctly and the switch still fails to light (no 
function), please contact your specialist dealer.

 

 

Figure 1:

   

       Rear Panel SxA360 

Summary of Contents for SxA360

Page 1: ...High Powered Loudspeaker Owner s Manual Bedienungsanleitung...

Page 2: ...armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmf...

Page 3: ...ure does not operate normally or has been dropped 14 To completely disconnect mains power from this apparatus the power supply cord must be unplugged 15 Do not expose this apparatus to dripping or spl...

Page 4: ...ang or fly the SxA two way systems please do so safely with the correct hardware and accessories WARNING Suspending any object is potentially dangerous and should only be attempted by individuals who...

Page 5: ...rds can be used to lengthen the ac cable as necessary but make sure that they are 3 conductor 14 gauge or greater and that are properly grounded to avoid electrical hazards and extraneous noise Be sur...

Page 6: ...ounterclockwise stop OUTPUT This connector is connected in parallel to the input allowing the through connection of the input audio signal LEVEL dB scaled level control for adjusting the power amp s o...

Page 7: ...ot kit contains two plastic feet The F200 is used with any 12 inch Sx or SxA speaker enclosures Insert the feet firmly into the holes in the rear cabinet see Figure 2 Remove the F200 monitor feet by p...

Page 8: ...Connectors Line Inputs Balanced Output XLR and 1 4 phone Combination XLR Power Requirement 95V 125V 195 250V 50 60Hz 78 Watts Enclosure Material Copolymer Grille Powder Coated Steel Dim H x W x D 23...

Page 9: ...High Powered Loudspeaker Bedienungsanleitung...

Page 10: ...INHALTSVERZEICHNIS Wichtige Sicherheits und Servicehinweise Safety First Beschreibung Bedienungselemente SxA360 Verwendung des SxA360 als Bodenmonitor Specifications Abmessungen Dimensions Block Diagr...

Page 11: ...etzsteckers wenn eine Fl ssigkeit in das Ger t gesch ttet wurde oder ein Gegenstand in das Ger t gefallen ist wenn das Ger t Regen oder Feuchtigkeit ausgesetzt wurde oder wenn es nicht normal arbeitet...

Page 12: ...zirkulation verbleiben Sie Electro Voice SxA Zweiweg Lautsprechersysteme im abgeh ngten oder geflogenen Betrieb ausschlie lich mit der geeignetem Hardware und entsprechendem Zubeh r sichern WARNUNG Da...

Page 13: ...zkabels verwendet werden wobei Sie zur Vermeidung von Kurzschl ssen und Rauscheinstreuungen darauf achten sollten dass die Verl ngerungskabel drei Leiter mit einem jeweiligen Mindestdurchmesser von 1...

Page 14: ...ler auf Linksan schlag drehen OUTPUT Diese Buchse dient zum Weiter schleifen des Eingangssignals und liegt direkt parallel zur Ein gangsbuchse LEVEL In dB skalierter Level Regler zur Anpassung der Ges...

Page 15: ...net sich zur Verwendung mit jedem 12 Inch Sx oder SxA Lautsprechersystem Stecken Sie die Standf e fest in die daf r vorgesehenen ffnungen in der Geh user ckseite siehe Abbildung 2 Entfernen Sie die F2...

Page 16: ...Connectors Line Inputs Balanced Output XLR and 1 4 phone Combination XLR Power Requirement 95V 125V 195 250V VAC 50 60Hz 78 Watts Enclosure Material Copolymer Grille Powder Coated Steel Dim H x W x D...

Page 17: ...17 BLOCKDIAGRAM...

Page 18: ...18 NOTES...

Page 19: ...19 NOTES...

Page 20: ...ille MN 55337 Phone 1 952 884 4051 FAX 1 952 884 0043 Germany EVI AUDIO GmbH Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 FAX 49 9421 706 265 Subject to change without prior noti...

Reviews: