Electro-Voice RE38N Brochure & Specs Download Page 2

RE38N/D Dynamic Cardioid Microphone

RE38N/D Dynamic Cardioid Microphone

2

field response shown is the output when the

sound source is at least 24 inches from the

microphone grille. The low frequency re-

sponse increases due to “proximity effect”

when the sound source is less than 24 inches

from the microphone. This low frequency

response will continue to increase as the

sound source moves closer to the micro-

phone. The amount of “proximity effect” in

the output of the microphone can be con-

trolled by placing the microphone at differ-

ent distances from the sound source and with

the equalization choices provided in the

RE38N/D. Positions 9 through 16 have the

same low frequency shape as the respective

positions 1 through 8, the difference being

that high end response is “bright” in  posi-

tions 9 through 16.

Architects’ and Engineers’

Specifications

The microphone shall be a dynamic cardioid

type with a wide uniform frequency response

from 70 to 20,000 Hz. The microphone shall

have bass-boosting “proximity effect” when

used up close and an easy to adjust equali-

zation switch permitting the selection of 16

different frequency response adjustments.

The open circuit voltage sensitivity shall be

2.5 mV/Pascal at 1000 Hz and the power

level sensitivity shall be -53 dB at 1000 Hz

where 0 dB equals 1 mW/Pascal. The mag-

netic circuit shall be a nonwelded circuit and

employ a neodymium alloy magnet. The

transducer shall employ a hum-buck coil

with a resulting hum sensitivity of -135 dBm

at 60 Hz in a 1 millioersted field and a shield

to prevent dust and iron particles from reach-

ing the diaphragm. Rated impedance shall

be 150 ohms. Line shall be balanced to

ground and phased. Pin 2 shall have a posi-

tive voltage with reference to Pin 3 with posi-

tive pressure on the diaphragm.

The microphone shall be supplied with a

Memraflex™ grille screen, pop filter and an

exceptional shock isolation system using

DynaDamp

TM

, an advanced foam elastomer

formulated for vibration control.

Response at any angular position away from

the major axis shall be essentially similar to

the response on the major axis, except at-

tenuated uniformly at all frequencies by an

amount appropriate to that angular position.

Polar characteristics shall be sufficiently uni-

form in all planes so that it is, effectively, a

cardioid of revolution.

Case material shall be aluminum and steel.

The microphone shall have a unique pivot-

ing yoke, detented to hold a set position, and

a stand adapter, to provide a highly flexible

mounting  system. The microphone shall have

a maximum height of 122 mm (4.8 in.), length

of 89 mm (3.5 in.), width of 109 mm (4.3 in.)

and a net weight of 380 grams (13.4 oz). The

finish shall be a non-reflecting satin nickel.

The microphone shall have a built-in cable

connector insert similar or equivalent to a

Switchcraft QG3M. Accessories shall in-

clude an 81715 stand adapter, carrying case

and 3/32 inch screwdriver.

The Electro-Voice RE38N/D is specified.

Limited Warranty

Electro-Voice products are guaranteed

against malfunction due to defects in mate-

rials or workmanship for a specified period,

as noted in the individual product-line

statement(s) below, or in the individual prod-

uct data sheet or owner’s manual, beginning

with the date of original purchase. If such

malfunction occurs during the specified pe-

riod, the product will be repaired or replaced

(at our option) without charge. The product

will be returned to the customer prepaid. Ex-

clusions and Limitations: The Limited

Warranty does not apply to: (a) exterior fin-

ish or appearance; (b) certain specific items

described in the individual product-line

statement(s) below, or in the individual prod-

uct data sheet or owner’s manual; (c) mal-

function resulting from use or operation of

the product other than as specified in the

product data sheet or owner’s manual; (d)

malfunction resulting from misuse or abuse

of the product; or (e) malfunction occurring

at any time after repairs have been made to

the product by anyone other than Telex Com-

munications, Inc. Service or any of its autho-

rized service representatives. Obtaining

Warranty Service: To obtain warranty ser-

vice, a customer must deliver the product,

prepaid, to Telex Communications, Inc. Ser-

vice or any of its authorized service repre-

sentatives together with proof of purchase

of the product in the form of a bill of sale or

receipted invoice. A list of authorized ser-

vice representatives is available from Telex

Communications, Inc. Service at 600 Cecil

Street, Buchanan, MI 49107 (800/234-6831

or FAX 616/695-4743).  Incidental and

Consequential Damages Excluded: Prod-

uct repair or replacement and return to the

customer are the only remedies provided to

the customer. Electro-Voice shall not be li-

able for any incidental or consequential dam-

ages including, without limitation, injury to

persons or property or loss of use. Some

states do not allow the exclusion or limita-

tion of incidental or consequential damages

so the above limitation or exclusion may not

apply to you. Other Rights: This warranty

gives you specific legal rights, and you may

also have other rights which vary from state

to state.

Electro-Voice Wired Microphones are

guaranteed against malfunction from any

cause for two (2) years from the date of origi-

nal purchase. In addition, the Limited War-

ranty for the acoustic system contained in

these microphones shall apply for the life of

the product, defined as a period of ten (10)

years from the date that the manufacture of

the specific microphone has been discontin-

ued. Any and all active electronics incorpo-

rated in these microphones are guaranteed

against malfunction due to defects in mate-

rials or workmanship for a period of three

(3) years from the date of original purchase.

The Limited Warranty does not extend to

cables, cable connectors, or switches. Addi-

tional details are included in the Uniform

Limited Warranty statement.

For  warranty repair or service informa-

tion, contact the service repair department

at: 616/695-6831 or  800/685-2606.

For technical assistance, contact Technical

Support at 800/234-6831 or 616/695-6831,

M-F, 8:00 a.m. to 5:00 p.m. Eastern Stan-

dard Time.

Specifications subject to change without

notice.

Summary of Contents for RE38N

Page 1: ...ent the RE38N D features a pivoting yoke configuration With the unique pivoting yoke the microphone can be easily adjusted to position the front toward the sound source The yoke positions are detented...

Page 2: ...products are guaranteed against malfunction due to defects in mate rials or workmanship for a specified period as noted in the individual product line statement s below or in the individual prod uct...

Page 3: ...RE38N D Dynamic Cardioid Microphone RE38N D Dynamic Cardioid Microphone 3 Figure 4 Switch Position 4 Figure 3 Switch Position 3 Figure 2 Switch Position 2 Figure 1 Switch Position 1...

Page 4: ...RE38N D Dynamic Cardioid Microphone RE38N D Dynamic Cardioid Microphone 4 Figure 8 Switch Position 8 Figure 7 Switch Position 7 Figure 6 Switch Position 6 Figure 5 Switch Position 5...

Page 5: ...RE38N D Dynamic Cardioid Microphone RE38N D Dynamic Cardioid Microphone 5 Figure 12 Switch Position 12 Figure 11 Switch Position 11 Figure 10 Switch Position 10 Figure 9 Switch Position 9...

Page 6: ...RE38N D Dynamic Cardioid Microphone RE38N D Dynamic Cardioid Microphone 6 Figure 16 Switch Position 16 Figure 15 Switch Position 15 Figure 14 Switch Position 14 Figure 13 Switch Position 13...

Page 7: ...rophone RE38N D Dynamic Cardioid Microphone 7 Figure 17 Polar Response at 250 Hz Figure 18 Polar Response at 1000 Hz Figure 20 Polar Response at 5000 Hz Figure 21 Dimensions Figure 19 Polar Response a...

Page 8: ...d Sensitivity Open Circuit Voltage 2 5 mV Pascal at 1000 Hz Power Level 53 dB at 1000 Hz 0 dB 1 mW Pascal Hum Pickup Level 135 dBm typical at 60 Hz in a 1 m OE field Magnetic Circuit N DYM magnet in a...