background image

6

en | Description

MFX Multi-Function Monitors

2019-06 | 01 | F.01U.361.835

Installation manual

Electro-Voice

2

Description

Thank you for choosing an Electro-Voice loudspeaker system. Please take time to consult the
manual to understand all the features built into your EV system and fully utilize its
performance capabilities.
MFX Multi-Function Monitors MFX-12MC and MFX-15MC are passive 12” and 15” coaxial
monitors with a performance level engineered to complement EV’s flagship X-Line Advance
(XLA) line array series.
MFX Multi-Function Monitors utilize high-output coaxially aligned HF and LF transducers and
an innovative, Electro-Voice engineered Constant Directivity waveguide. The dimensions and
location of the waveguide interact with the woofer to effectively create a bipole output,
resulting in precise coverage control through the midrange to the upper frequencies. In
addition to providing a stable sound image as the performer moves off-axis, the compact
coaxial design presents a significantly lower-profile footprint on stage in comparison to
competitive high-end monitors, helping to maintain audience sight lines and reducing stage
clutter. Dual monitor angles allow the enclosure to be precisely directed toward the
performer, while the rugged EVcoat finish and 1.5 mm-thick corrosion-resistant grille combine
professional-grade durability with sleek aesthetics.
These two high-performance stage monitors have a truly multi-functional design. They feature
pole sockets recessed into the side handles for use as short-throw reinforcement in portable
applications. U brackets, yokes, truss clamps, stand-mount adapters, and a rigging bar round
out a full range of mounting accessories for temporary or permanent installation.
In addition to their primary use as stage monitors, these models are also excellent solutions as
side fill, front fill, and delay speakers, as distributed speakers for events, or as the main
speakers for smaller jobs. Target applications include live performance, large corporate
events, worship services and concerts. The multi-functional aspect of the speakers makes
them an attractive investment for production, rental, and live sound companies because the
speakers can be deployed in multiple system roles, keeping more of the rental inventory
working rather than sitting in the warehouse until an appropriate job is booked.
The monitors can be used in passive or biamp configuration. Multiple DSP settings optimize
the speakers for specific uses. The recommended amplifiers for the MFX Multi-Function
Monitors are the TGX and IPX series from EV’s sibling brand, Dynacord.

2.1

Features

MFX-12MC 12-inch two-way coaxial multi-function monitor

High-output, passive/biamp coaxial designs with constant directivity waveguides ensure a
stable sound image even when the performer is off-axis

135 dB SPL maximum output, measured one meter on-axis free-field with 12 dB crest
factor pink noise

Versatile design for both high-performance stage monitoring and short-throw applications

Design accepts a standard pole mount and a full range of accessories for use in
temporary sound reinforcement or in permanent installs

Multiple DSP setting choices optimize the speakers for intended application

Summary of Contents for MFX Series

Page 1: ...MFX Multi Function Monitors MFX 12MC B MFX 12MC W MFX 15MC B MFX 15MC W en Installation manual ...

Page 2: ......

Page 3: ... Important safety instructions 4 1 2 Suspension 4 1 3 Precautions 4 1 4 Notices 5 2 Description 6 2 1 Features 6 3 Monitor and pole mount operation 8 3 1 Monitor operation 8 3 2 Tripod or pole mount operation 9 4 Suspension 10 5 Recommended configuration 11 5 1 Passive and biamp configuration 11 5 2 Amplifier configuration 13 6 Dimensions 14 ...

Page 4: ... sign of weakness or damage is detected remedial action should be taken immediately The user is responsible for making sure the wall ceiling or structure is capable of supporting all objects suspended overhead Any hardware used to suspend a loudspeaker not associated with Electro Voice is the responsibility of others Warning Do not suspend this product in any other manner than explicitly described...

Page 5: ...nic devices you should use the return and collection systems put in place in the country concerned NEUTRIK speakON powerCON and etherCON are registered trademarks of Neutrik AG Copyright and disclaimer All rights reserved No part of this document may be reproduced or transmitted in any form by any means electronic mechanical photocopying recording or otherwise without the prior written permission ...

Page 6: ...ndles for use as short throw reinforcement in portable applications U brackets yokes truss clamps stand mount adapters and a rigging bar round out a full range of mounting accessories for temporary or permanent installation In addition to their primary use as stage monitors these models are also excellent solutions as side fill front fill and delay speakers as distributed speakers for events or as...

Page 7: ...able sound image even when the performer is off axis 136 dB SPL maximum output measured one meter on axis free field with 12 dB crest factor pink noise Versatile design for both high performance stage monitoring and short throw applications Design accepts a standard pole mount and a full range of accessories for use in temporary sound reinforcement or in permanent installs Multiple DSP setting cho...

Page 8: ...pporting surface so that its main axis is pointed at the performer 3 Safely route cables to prevent injury to performers production crew and audience members Using the alternate 35 monitor angle Using the alternate 35 monitor angle the loudspeaker can be set up as a distant use floor monitor a drum monitor a keyboard monitor or a side fill Figure 3 2 Monitor angle for distant use To set up a louds...

Page 9: ...ure 3 3 MFX on a tripod stand left Short medium throw coverage right Caution Tripod is not evaluated for safety with this loudspeaker Check the specifications of the tripod stand to be certain it is capable of supporting the weight of the loudspeaker To mount a loudspeaker on a tripod stand do the following 1 Place the tripod stand on a level and stable surface Fully extend the legs on the tripod ...

Page 10: ...s overhead Electro Voice strongly recommends that loudspeakers be suspended taking into account all current national federal state and local laws and regulations It is the responsibility of the installer to ensure all loudspeakers are safely installed in accordance with all such requirements When loudspeakers are suspended Electro Voice strongly recommends the system be inspected at least once per...

Page 11: ...nded configuration en 11 Electro Voice Installation manual 2019 06 01 F 01U 361 835 5 Recommended configuration 5 1 Passive and biamp configuration Passive mode Passive speakON NL4 Passive internal schematic HF LF 1 1 2 2 1 1 2 2 HPF LPF ...

Page 12: ...12 en Recommended configuration MFX Multi Function Monitors 2019 06 01 F 01U 361 835 Installation manual Electro Voice Biamp mode Biamp speakON NL4 Biamp internal schematic HF LF 1 1 2 2 1 1 2 2 ...

Page 13: ... Installation manual 2019 06 01 F 01U 361 835 5 2 Amplifier configuration TGX10 or TGX20 amplifier Maximum four speakers per channel Passive or Biamp mode 2 Passive mode 1 Passive mode 1 Passive or Biamp mode 2 Figure 5 1 TGX amplifier 1 Passive mode 2 Passive or Biamp mode ...

Page 14: ...14 en Dimensions MFX Multi Function Monitors 2019 06 01 F 01U 361 835 Installation manual Electro Voice 6 Dimensions Figure 6 1 Dimensions MFX 12MC 1 Center of gravity ...

Page 15: ...MFX Multi Function Monitors Dimensions en 15 Electro Voice Installation manual 2019 06 01 F 01U 361 835 Figure 6 2 Dimensions MFX 15MC 1 Center of gravity ...

Page 16: ...Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2019 Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 USA www electrovoice com Bosch Security Systems Inc 2019 ...