Electrical connection

Low impedance connection

All EVC full-range systems are passive, meaning that the internal crossover/equalizer network
sends low frequencies to the woofer and high frequencies to the compression-driver/
waveguide combination. In addition, the network tailors the frequency response and level of
each individual driver so that the overall frequency response of the loudspeaker is essentially
flat over its intended range of operation. There is no bi-amp option for EVC full-range
loudspeakers.

Figure 6.1: EVC input panel

The screw terminals on the input panel will accept wire gauges as large as AWG 10. There are
two pairs of terminals l and -. A speaker-level audio signal should be connected to one
of these +/- pairs. The other +/- pair can be used to connect one or more additional
loudspeakers in parallel, as long as the combined load impedance does not drop too low for
the amplifier to operate reliably. When the TK-150 audio transformer is installed in an EVC
loudspeaker, the ASC feature will automatically keep the impedance of each loudspeaker in a
safe range. The two pairs of connections marked THRU are wired as pass-through connections
for a separate audio signal.
 
Optional speaker processing
Once an EVC loudspeaker is installed in a venue a digital signal processor (DSP) will typically
be used to adjust the in-room frequency response. In addition, the DSP should be used to
provide the high-pass filters recommended to protect the EVC-1122-VI from overdrive at
frequencies below its operating range. Failure to do so could damage the low-frequency driver
if the system is subjected to high-level signals below its operating range. The recommended
high-pass filter frequencies for infrasonic protection of the EVC-1122-VI is:

6

6.1

EVC Variable-Intensity Loudspeaker

  

2018.01 | 01 | F.01U.345.997

Installation manual

Electro-Voice

Summary of Contents for EVC-1122-VIB

Page 1: ...EVC Variable Intensity Loudspeaker EVC 1122 VIB EVC 1122 VIW en Installation manual...

Page 2: ......

Page 3: ...mended pre installation procedures 9 4 3 Working with mounting accessories 10 4 3 1 Mounting with a U bracket 10 4 3 2 Mounting with rigging points 11 5 Rigging strength ratings and safety factors 13...

Page 4: ...strongly recommends the system be inspected at least once per year or as laws and regulations require If any sign of weakness or damage is detected remedial action should be taken immediately The use...

Page 5: ...that are no longer serviceable must be collected separately and sent for environmentally compatible recycling in accordance with the European Waste Electrical and Electronic Equipment Directive To di...

Page 6: ...C which preserves low frequency performance while presenting a stable load to the amplifier regardless of the number of speakers connected in parallel As a result EVC loudspeakers including the subwoo...

Page 7: ...d short throw loudspeakers We ve also eliminated the cost of a properly designed two box system which needs to include another power amplifier channel for proper power control and impedance matching L...

Page 8: ...ng height measurement the vertical throw will be about three times the mounting height There is a small area of reduced coverage on the floor directly in front of the loudspeaker which will help incre...

Page 9: ...recommended even if the loudspeaker shows no external damage When shipping the loudspeaker make sure to always use its original box and packaging materials By packing the loudspeaker exactly as it was...

Page 10: ...ciated with Electro Voice is the responsibility of others Mounting with a U bracket Caution It is the installer s responsibility to determine and use the proper mounting hardware for the wall construc...

Page 11: ...cessary to order one of the accessory eyebolt kits sold separately EBK M10 3PACK optional eyebolt kit consisting of three M10 shoulder eyebolts and three fender washers used when eyebolts are needed t...

Page 12: ...e eyebolt until the correct alignment position is obtained A maximum of one complete turn 4 Install a safety cable Eyebolts orientated in the plane of pull Caution Eyebolts must be fully seated and or...

Page 13: ...that exceeds 100 lb 45 4 kg The safety factor provides a margin of safety above the WLL to accommodate normal dynamic loading and normal wear Cautions for working load limits and safety factors The W...

Page 14: ...nder any circumstances If a safety factor higher than 10 1 is required the angle limits for each eyebolt may actually decrease to a number less than what is shown in Suspension line angle limits for i...

Page 15: ...t suspension lines Left to right all eyebolt suspension angles The suspended all eyebolt cluster must be perpendicular plumb to within 5 5 MAX Figure 5 3 Left to right angle limits for an all eyebolt...

Page 16: ...s long as the combined load impedance does not drop too low for the amplifier to operate reliably When the TK 150 audio transformer is installed in an EVC loudspeaker the ASC feature will automaticall...

Page 17: ...stand alone DSP loudspeaker controller or in the processing section of a DSP enabled amplifier L Series and C Series amplifiers from Dynacord are recommended for use with EVC loudspeakers because the...

Page 18: ...ors Dual four pin 10 AWG Phoenix Euro Block screw terminals Enclosure 15 mm plywood with EVCoat Grille 18 GA powder coated steel with rotatable logo Environmental IEC 60529 IP44 Suspension 8 M10 suspe...

Page 19: ...equency response and impedance Dimensions 69 63 276 6 mm 10 89 in 411 0 mm 16 18 in 527 8 mm 20 78 in 647 6 mm 25 50 in 202 0 mm 7 95 in en 19 Electro Voice Installation manual 2018 01 01 F 01U 345 99...

Page 20: ...the low frequency extension of the system by adding incremental filtering only to the extent required by the current level in the loudspeaker Following the parameters below the TK 150 is capable of de...

Page 21: ...hereof Notice Tighten all unused connector screws to prevent rattles Notice The TK 150 ships with two input panel labels one label is for standard use and one label is for EN54 24 Voice alarm systems...

Page 22: ...s 8 Apply the new label supplied over the input connectors 9 Connect the input line to the COM input terminal and the input line to the terminal corresponding to the desired wattage in either the 70 7...

Page 23: ...ctions from water Note that this cover is supplied with the PI versions CSG optional single gland nut input panel cover to protect the input connections from water CDNL4 optional input panel cover equ...

Page 24: ...hnson City TN 2014 8 Newberry W G Handbook for Riggers Newberry Investments Company Calgary Alberta Canada 1989 1 All other trademarks are property of their respective owners Mechanical engineering pr...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...tssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2018 Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 USA www e...

Reviews: