6

Figure 4—Directivity

The directivity index, D

i

, and directivity fac-

tor, R

 

θ

 (Q), of the system were measured

with a full spherical measurement system

as described for the "Polar Response."

Figure 5—Distortion

Distortion for the system was measured

on axis in the farfield in an anechoic envi-

ronment with an input signal that would

result in a sound-pressure level of 115 dB

at one meter.  The Dx34 digital electronic

unit was used to provide the necessary

crossover filters, equalization and time de-

lay. A frequency spectrum typical of close-

mic’d rock music was employed. The

sound-pressure level was normalized for

an equivalent one-meter distance. Plots of

second and third harmonic distortion are

shown referenced to the fundamental.

Figure 3—Beamwidth

The beamwidth of the system, (i.e., the in-

cluded horizontal and vertical coverage

angles at the 6-dB down point) was mea-

sured with a full spherical measurement

system as described in "Polar Response."

Summary of Contents for DeltaMax DMS-1152/64 Series

Page 1: ...distortion through the critical vocal frequencies The DH2T compression driver is coupled to the HP64M flat front constant directiv ity horn This 60 x 40 design is optimized for performance from 800 Hz...

Page 2: ...the DMS speakers will not be realized The use of amplifiers with signifi cantly higher power ratings will generate maximum dynamic range and fidelity but care must be utilized for longer duration sig...

Page 3: ...a sheet or owner s manual be ginning with the date of original purchase If such malfunction occurs during the specified period the product will be re paired or replaced at our option without charge Th...

Page 4: ...3 octave filtered pink noise with a full spherical measurement system The Dx34 digital electronic unit was used to provide the necessary crossover filters equalization and time delay The polar respon...

Page 5: ...echoic environment using a swept sine wave signal The Dx34 digital electronic unit was used to provide the necessary crossover filters equalization and time de lay One watt of power 2 83 volts rms at...

Page 6: ...lt in a sound pressure level of 115 dB at one meter The Dx34 digital electronic unit was used to provide the necessary crossover filters equalization and time de lay A frequency spectrum typical of cl...

Page 7: ...MS 1152 64LoudspeakerSystem 7 HF LF Figure 6 Impedance The impedance of each frequency band of the system was measured in an anechoic environment Figure 7 Wiring Diagram The wiring diagram of each fre...

Page 8: ...Hz Average see Figure 4 13 0 dB 1 4 dB 1 8 dB Distortion 115 dB SPL at one meter shaped spectrum see Figure 5 Second Harmonic 100 Hz 1 6 500 Hz 0 9 2 000 Hz 1 3 5 000 Hz 1 0 Third Harmonic 100 Hz 0 3...