POWER AMPLIFIER OUTPUT CONNECTORS  

SPEAKON output connectors are provided for the power
amplifier channels A (left) and B (right).

The Bridged Out Connector for bridged operation is
sealed with a plastic cover to prevent connection errors.

LIMITER

The time constant of the built-in limiter to avoid overdri-
ving is adjustable. Position “SLOW” is the factory preset
and this should also be the normal position.

If the power amplifier is used as a MID/HI-frequency
amplifier in active multi-way systems, the limiter switch
should be set to 

“FAST”

.

If the power amplifier is used as LOW-frequency ampli-
fier in active multi-way systems, the limiter switch should
be set to 

“SLOW”

.

BRIDGED MODE

Slide switch to change from Normal Stereo mode to
Bridged mode. In Bridged mode the built-in power ampli-
fiers operate in “push- pull” and the double output voltage
from channel A and B appears at the Bridged output
connector. The phases of Channel A and B are in oppo-
site and therefore the individual channels must not be
used as loudspeaker outputs.

HI-LO-CUT FILTER

This filter attenuates subsonic and high frequency si-
gnals so that the power amplifiers are not modulated with
these signals. This switch should normally always be in
position ON. The OFF position is only for applications
where an upstream unit, e.g. a crossover or a equalizer,
has integrated HI-Cut and LO-Cut filters.

GROUNDLIFT SWITCH

Hum loops can be avoided with the groundlift switch. If
the power amplifier is operated together with other units
in one 19" rack, the switch should be in GROUNDED
position. If the power amplifier is used with units which
have different earthing potentials, the switch should be
adjusted to the UNGROUNDED position.

REAR PANEL

12

Summary of Contents for Contractor Precision CPS3

Page 1: ...OWNER S MANUAL CPS 3 CPS 4 CONTRACTOR PRECISION SERIES...

Page 2: ...into your outlet consult an electrican for replacement of the absolete outlet 1 Security regulations as stated in the EN 60065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the a...

Page 3: ...by far No V I Foldback Limiter circuits are employed within the power amplifiers making it possible to operate the amps on complex loads up to 90 phase angles without a problem The input facilities a...

Page 4: ...eaker line has shorted or a protective circuit has been activated thus indicating that there is no signal at the speaker output terminals 5 LIMIT This LED lights up if the limiter has been activated a...

Page 5: ...0 dBu The power amplifier can be set internally to 6dBu input sensitivity or to 26dBu gain INPUT ROUTING PARALLEL MONAURAL Setting the selector switch to the PARALLEL MONO position puts the channel A...

Page 6: ...ode the built in power ampli fiers operate in push pull and the double output voltage from channel A and B appears at the Bridged output connector The phases of Channel A and B are in oppo site and th...

Page 7: ...Sensitivity 0dBu 775mV at rated output power 4 1 kHz THD at rated output power 0 05 MBW 80kHz 1 kHz IMD SMPTE 0 01 60 Hz 7 kHz DIM30 0 01 3 15kHz 15 kHz Crosstalk 70 dB ref 1kHz at rated output power...

Page 8: ...BLOCK DIAGRAM 20...

Page 9: ...Abmessungen Dimensions in mm ABMESSUNGEN DIMENSIONS 21...

Reviews: