Features 

 

Long-life, 99.97% HEPA (High Efficiency Particulate Air) Media Filter  
removes particles 0.3 micron and larger 
Carbon Prefilter removes lint and large particles, to extend life of HEPA Filter 
Two High Output Ultraviolet Germicidal Lamps 
CinQuartz™ Photo Catalytic Oxidation Filter removes unpleasant odors 
and Volatile Organic Compounds 
Carbon/ Potassium Permanganate Final Filter removes non-organic gases 
Kills or inhibits bacteria, viruses, mold, fungi and microbial growth 
Easy-to-change Filters and Lamps 
Powerful motor delivers 250 CFM (FSDM900UV-VO-A) or up to 250 CFM (FSDM900UV-VO-VS, 
Variable Speed) of clean, sterilized air 
Heavy gauge galvanized steel cabinet and external powder-coat paint finish provides rigid 
installation and durability 
Plug-in Power Cord provides easy electrical connection 
Versatile installation can be duct mounted, collar mounted or used as stand alone unit. 
Stands with or without wheels optional 

Summary of Contents for EADM900UV-VO-A

Page 1: ...Photo Catalytic Oxidation Filter removes unpleasant odors and Volatile Organic Compounds Carbon Potassium Permanganate Final Filter removes non organic gases Kills or inhibits bacteria viruses mold fungi and microbial growth Easy to change Filters and Lamps Powerful motor delivers 250 CFM FSDM900UV VO A or up to 250 CFM FSDM900UV VO VS Variable Speed of clean sterilized air Heavy gauge galvanized ...

Page 2: ...time and redecorating costs Provides a healthier more comfortable environment year round HOW IT WORKS Millions of airborne pollutants are carried through the return air ducts of the heating cooling system The Air Cleaner has been designed to be installed on the return air duct A portion of this return air is by passed through an opening on the rear or top of the unit and passes through a 5 stage f...

Page 3: ... the holes on the top or bottom of the unit if you are duct mounting the Air Cleaner Bend all the flaps outward slightly less than 90 degrees except for the upper bottom flap which is only bent up 45 degrees This bottom flap will act as a deflector for the exhaust air entering back into the plenum 5 Place the gasket material around the two openings on the back of the air cleaner 6 Place the unit o...

Page 4: ...r direct it should be added to the system before the intake inlet to the Air Cleaner 5 The 8 inch intake collar top must draw air from the return duct at a location that will be ahead of the clean exhaust air that will be returned to the duct from the Air Cleaner An 8 inch collar will be installed on the return duct and a length of 8 inch flexible hose or duct is required to attach between the 8 i...

Page 5: ... cord to be placed where it may be walked on or allow anything to roll over it MAINTENANCE For efficient operation the filters must be changed on a regular basis If you notice a reduction in air flow from the system check the filters WARNING Never use the Air Cleaner without all of the filters in place and all cover panels and doors closed Make sure all the screws are in place CAUTION Make sure to...

Page 6: ...tancy of the HEPA filter Note Handle the HEPA filter by the frame only The paper is fragile and a puncture or tear will reduce efficiency Replacing the UV Lamps PCO Filter and Final Filter 1 To change the PCO filter Final filter and UV lamps turn the Air Cleaner OFF and UNPLUG it Remove the screws from the lamp access panel and remove the panel DO NOT misplace the parts 2 Carefully remove the filt...

Page 7: ... 1002 Contains 2 UVC lamps 2 lamp support clips 1 PCO filter and gloves Complete 2 Year Maintenance Kit DM900 1003 Contains 1 HEPA filter 4 carbon prefilters 2 UVC lamps 1 PCO filter 2 carbon potassium permanganate final filters gloves Dimensions Height Width Depth 29 5 in 16 25 in 12 75 in 74 9 cm 41 3 cm 32 4 cm Intake 14 5 x 3 75 in or 8 in dia 36 8 x 9 5 cm or 20 3 cm dia Outflow 14 5 x 4 37 i...

Page 8: ...bility are hereby limited in duration to the period for which the limited warranty is given The expressed warranties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor dealer or other person whatsoever ELECTRO AIR CANADA WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the Owner s Manual including cleaning and or replacement of filters ...