ElectrIQ SILENT16 User Manual Download Page 11

Page 11 of 14 

MAINTENANCE 

CLEANING 

PLEASE TURN OFF THE UNIT AND UNPLUG FROM THE MAINS BEFORE CLEANING OR 
PERFORMING ANY MAINTENANCE 

 

CLEAN THE SURFACE   

Clean the surface of the machine with a wet soft cloth. Do not use chemicals, such as benzene, alcohol, 
gasoline, etc; otherwise, as this may cause damage to the surface and or the internal workings of the 
machine 

 

AIR FILTER CLEANING 

If the filter screen is clogged with dust, the effectiveness of the air conditioner is reduced. The filter screen 
should be cleaned once every two weeks or as often as necessarily in your environment.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

CLEAN THE UPPER FILTER SCREEN FRAME 

Grip the edge of the evaporator filter screen frame with both hands. Pull out to remove the filter screen 
from its frame. If present, unscrew the screws fixing the filter before removing it (as shown in the above 
figure).                                                   
Put the evaporator filter screen into warm water with neutral detergent (about 40

Ԩ

 /104

Ԭ

) and dry it in 

the shade after rinsing clean.       

 
CLEAN THE LOWER FILTER SCREEN FRAME 

Hold the handle of the air inlet filter screen frame, and pull it outward gently to remove it. 
Put the filter screen into warm water with neutral detergent (about 40

Ԩ

 / 104 

Ԭ

) and dry it in the shade 

after rinsing clean. 

                                                     

END OF SEASON MAINTENANCE 

1.  Remove the rubber stopper and drain plug cap from the drainage hole and empty the internal 

tank. You can also drain the water by leaning the unit.   

2.  Then switch the unit to low fan mode. 
3.  Keep the unit in this mode for half day - until the conduit is dried. Doing this helps to keep the 

inside of the unit dry and prevents mould from developing   

4.  Turn off the unit and pull out the plug. 
5.  Replace the rubber stopper and drain plug cap 
6.  Coil the wire and bind it together, then put it into the accessories space.   
7.  Separate the air-exhaust pipe and store it safely.     
8.  Cover the unit and keep it in a dry place.   
9.  Take the batteries out of the remote control and store or dispose of them safely   

Keep all accessories with the unit ready for next season.   

 

Summary of Contents for SILENT16

Page 1: ...NDITIONER Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co uk for our enti...

Page 2: ...TENTS SAFETY INSTRUCTIONS 3 OPERATION 8 REMOTE CONTROL 8 EMPTYING THE INTERNAL WATER TANK 10 MANUAL DRAINAGE 10 MAINTENANCE 11 CLEANING 11 END OF SEASON MAINTENANCE 11 TROUBLESHOOTING 12 APPENDIX 13 T...

Page 3: ...in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be installed by a qualified electrician Never operate this appliance if the co...

Page 4: ...ompromised the refrigerant system Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer Before opening and servicing the unit the authorized engineer must be...

Page 5: ...operation mode z On Off timer function allows you to choose when the unit operates z Compressor protection technology PARTS LIST Extendable Exhaust Hose Slide Bar Control panel Top cover Front housing...

Page 6: ...attached At least 3 full rotations 2 Attach the connector on the opposite end of the pipe to the exhaust outlet on the rear of the appliance by putting it into position and twisting to lock in place 3...

Page 7: ...room while efficiently cooling it Your air conditioner should be used without the vent pipe in dehumidifier mode When using dehumidifier mode ensure that an external water tank is used monitored and r...

Page 8: ...FY MODE The fan will default to low speed and cannot be adjusted TIMER BUTTON Timer functions cannot be combined or repeated POWER ON TIMER With the appliance turned off press the TIMER button to setu...

Page 9: ...the sleep mode The unit will work with energy saving logic and the lowest fan speed MULTI PROTECTIVE FUNCTIONS OVERFLOW PROTECTION FUNCTION When the water in the internal water tank exceeds the warni...

Page 10: ...k Put the rubber stopper back into place CONTINUOUS DRAINAGE Unscrew the drain plug cap and remove the rubber stopper Connect a water pipe to the water outlet Not Supplied You can plumb this pipe into...

Page 11: ...al detergent about 40 104 and dry it in the shade after rinsing clean CLEAN THE LOWER FILTER SCREEN FRAME Hold the handle of the air inlet filter screen frame and pull it outward gently to remove it P...

Page 12: ...is user manual and hose is not bent Loud Noise The air conditioning is not placed on a flat surface Put the air conditioning on a flat and hard place to reduce noise Compressor does not work Overheat...

Page 13: ...ase be considerate when depositing your equipment Please contact the local council for details of your local household waste recycling centres TECHNICAL DATA MODEL SILENT1 V2 Capacity Cooling kWh 1 00...

Page 14: ...omplete the online form 0871 620 1057 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to se...