MAINTENANCE  

CLEANING  

PLEASE SHUT OFF THE UNIT AND UNPLUG FROM THE MAINS BEFORE CLEANING OR 

PERFORMING ANY MAINTENANCE 

 

CLEAN THE SURFACE   

Clean the surface of the machine with a wet soft cloth. Do not use chemicals, such as benzene, alcohol, 
gasoline, etc; otherwise, as this may cause damage to the surface and or the internal workings of the 
machine 

 

AIR FILTER CLEANING  

If the filter screen is clogged with dust, the effectiveness of the air conditioner is reduced. The filter screen 
should be cleaned once every two weeks or as often as necessarily in your environment.  

 

 

CLEAN THE UPPER FILTER SCREEN FRAME  

Grip the edge of the evaporator filter screen frame with both hands. Pull out to remove the filter screen 
from its frame. If present, unscrew the screws fixing the filter before removing it (as shown in the above 
figure).    

 

Put the evaporator filter screen into warm water with neutral detergent (about 40

 /104

) and dry it in 

the shade after rinsing clean.    

 

CLEAN THE LOWER FILTER SCREEN FRAME  

Hold the handle of the air inlet filter screen frame, and pull it outward gently to remove it. 

 

Put the filter screen into warm water with neutral detergent (about 40

 / 104 

) and dry it in the shade 

after rinsing clean. 

 

END OF SEASON MAINTENANCE  

1.  Remove the rubber stopper from the drainage hole and empty the internal tank. You can 

also drain the water by leaning the unit.

 

2.  Then switch the unit to low fan mode.

 

3.  Keep the unit in this mode for half day - until the conduit is dried. Doing this helps to 

keep the inside of the unit dry and prevents mould from developing

 

4.  Turn off the unit and pull out the plug.

 

5.  Replace the rubber stopper.

 

6.  Coil the wire and bind it together, then put it into the accessories space.

 

7.  Separate the air-exhaust pipe and store it safely.

 

8.  Cover the unit and keep it in a dry place.

 

9.  Take the batteries out of remote control and store or dispose of them safely. Keep all 

accessories with the unit ready for next season.

 

Summary of Contents for SILENT10

Page 1: ...NDITIONER Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co uk for our enti...

Page 2: ...TIONS 3 FEATURES 5 PARTS LIST 5 INSTALLATION 6 OPERATION 8 REMOTE CONTROL 9 EMPTYING THE INTERNAL WATER TANK 10 MANUAL DRAINAGE 10 MAINTENANCE 11 CLEANING 11 END OF SEASON MAINTENANCE 11 TROUBLESHOOTI...

Page 3: ...ed with this appliance Do not clean the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be...

Page 4: ...carried out on the unit by a suitably qualified engineer Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer s service manual and must fol...

Page 5: ...xury model Bright LED screen indicates temperature and operation mode On Off timer function allows you to choose when the unit operates Compressor protection technology PARTS LIST ACCESSORIES 1 Extend...

Page 6: ...e hose and screw into the exhaust connector At least 3 full turns 3 Push the Exhaust Connector onto the Exhaust outlet on the rear of the unit 4 Make sure the unit is upright and there are no obstruct...

Page 7: ...air from your room while efficiently cooling it Your air conditioner should be used without the vent pipe in dry mode When using dry mode ensure that an external water tank is used monitored and regul...

Page 8: ...of hours POWER OFF TIMER With the appliance running with the desired settings press the TIMER button to setup the power off timer Press the UP and DOWN buttons to adjust the duration of the timer fro...

Page 9: ...hile in Cooling Mode the compressor and water motor will stop working If the copper coil temperature reaches 2 C for over 20 seconds When the copper coil temperature increases to 8 C the protection wi...

Page 10: ...drain from the internal tank Put the rubber stopper back into place CONTINUOUS DRAINAGE Remove the rubber stopper from the continuous drainage port Connect a water pipe to the water outlet You can plu...

Page 11: ...warm water with neutral detergent about 40 104 and dry it in the shade after rinsing clean CLEAN THE LOWER FILTER SCREEN FRAME Hold the handle of the air inlet filter screen frame and pull it outward...

Page 12: ...user manual and hose is not bent Loud Noise The air conditioning is not placed on a flat surface Put the air conditioning on a flat and hard place to reduce noise Compressor does not work Overheat pr...

Page 13: ...te when depositing your equipment Please contact the local council for details of your local household waste recycling centres TECHNICAL DATA MODEL SILENT10 V3 SILENT10E V3 Capacity Cooling 2 64kWh 9...

Page 14: ...te the online form 0871 620 1057 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if...

Reviews: