INSTALLATION 

Warning

Before using this unit, please keep it upright for at least 3-4 hours.   

This unit can easily be moved from one room to another.   
While moving the unit please note that it must always be kept upright and then placed on 
an even surface. 

1. 

Assemble  the  fishtail  adaptor  on  to  the  hose,  by  extending  the  end  of  the  hose  and 
twisting the fishtail into position (At least 3 full rotations) 

 

 

 

 

 

2. 

Assemble the Exhaust hose connector on to the other end of the hose, by extending the 
opposite end of the hose and twisting the outlet into position (At least 3 full rotations) 

 

 

 

 

 

 

 

 

3. 

Attach the Exhaust hose connector to the 
rear of the air conditioner 

           

                                                   

 

 

 

 

4. 

Make sure the unit is upright and there are no 
obstructions to the air inlets and outlet grills.    A minimum 
of 50cm clearance should be left between the inlet/outlet 
grills and any obstruction. 

 

 

Summary of Contents for P16HP

Page 1: ...ITH HEATPUMP P16HP P18HP Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co...

Page 2: ...Page 2 of 15 CONTENTS SAFETY INSTRUCTIONS 3 FEATURES AND PARTS LIST 5 INSTALLATION 7 OPERATION AND SETTINGS 9 WATER DRAINAGE 11 MAINTENANCE 12 TROUBLESHOOTING 13 APPENDIX 14...

Page 3: ...nit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be installed by a qualified electrician Neve...

Page 4: ...authorized technicians Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer Before opening and servicing the unit the authorized engineer must be in posses...

Page 5: ...LED screen indicates temperature and operation mode Enhanced design with hot air outlet positioned higher This allows for improved performance with the use of a short hose 24 hour programmable timer...

Page 6: ...Page 6 of 15 PARTS LIST ACCESSORIES Rear cover SIDE VIEW Castor FRONT VIEW Control Panel REAR VIEW Plug Air Inlet Exhaust Hose Fishtail Connector Slide Bar Remote Control Exhaust hose connector...

Page 7: ...he end of the hose and twisting the fishtail into position At least 3 full rotations 2 Assemble the Exhaust hose connector on to the other end of the hose by extending the opposite end of the hose and...

Page 8: ...indow However the fish tail adaptor can be used with most windows doors When using cooling or heating modes ensure that the opening is left as small as possible The best form of installation is throug...

Page 9: ...The unit should be set up without a vent hose moisture is extracted from the air that passes through the unit Continuous drainage should be set up for the moisture collected FAN MODE No cooling effec...

Page 10: ...number of hours time you desire the unit to start by using the UP and DOWN buttons 2 Once the set time has elapsed the unit will turn on automatically 3 Press the POWER button before the time has elap...

Page 11: ...o place CONTINUOUS DRAINAGE 1 Unscrew the water plug A and remove the rubber bung B 2 Connect a suitably sized water pipe to the port 3 You can plumb this pipe into your current plumbing system lead i...

Page 12: ...about 40 water with a neutral detergent f Rinse it and then dry it thoroughly g Carefully re install air filters back into their cover Please note If in use the optional active carbon filter cloth sho...

Page 13: ...e The unit loud The unit is not put on flat surface Put the unit on flat and hard surface Compressor does not work Overheating protection is active Check venting Restart the unit after 5 minutes when...

Page 14: ...ur local household waste recycling centres TECHNICAL DATA P16HP P18HP Capacity Cooling 4 6 kWh 16 000 BTU Cooling 5 2 kWh 18 000 BTU Heating 4 2 kWh 14 000 BTU Heating 4 7 kWh 16 000 BTU Rated Input C...

Page 15: ...1 620 1057 or complete the online form 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to s...

Reviews: