background image

11 

 

CARBON FILTER

OPTIONAL

 

 

Activated carbon filters should be used to trap odours (optional 

– available 

from the same stockist you purchased the hood from) and must be used if the 
hood is not vented to the outside. Reference: 
 
 

eiQCF110 Carbon Filter Pack

– fits model eiQCHA90B, eiQCHA90SS 

 
 
 
In order to install the activated carbon filters, the aluminium filter should be 
removed first. Press the lock and pull it downward as below: 
 
 

     

 
 
 

Put the activated carbon filter onto the end of the motor unit and turn it in anti-

clockwise direction. Repeat the same on the other side (see diagram). 

 

NOTE: 

  Make sure the filter is securely locked. Otherwise, it could loosen and 

cause damage to the unit. 

  When the activated carbon filters are attached, the suction power will 

be lowered. 

  The charcoal filter cannot be washed or recycled. It should be changed 

at three or six months according to the amount of use the hood 
receives. Replacements are available from the stockist you purchased 
the hood from.   

 

 
 
 
 

 

Summary of Contents for eiQCHA90B

Page 1: ...UCH CONTROL COOKER HOOD eiQCHA90B eiQCHA90SS Thank you for choosing electriQ Please read this user manual before using this product and keep it safe for future reference Visit our page www electriQ co...

Page 2: ...2 CONTENTS SAFETY 3 PRODUCT OVERVIEW 5 VENTING OPTIONS 6 INSTALLATION 7 FILTER INFORMATION 11 OPERATION 12 CLEANING AND MAINTENANCE 13 TROUBLESHOOTING 14 TECHNICAL SPECIFICATION 15 SUPPORT 16...

Page 3: ...cessively greasy They should be cleaned regularly see Maintenance or replaced as necessary The extraction fan must be level to avoid grease collection at one end as this could cause a potential fire r...

Page 4: ...ugh a suitable sized opening which cannot be sealed during operation A number of alternative solutions are available to ensure this If in any doubt professional advice should be sought Regulations con...

Page 5: ...ERVIEW PARTS SUPPLIED Description Illustration Qty Cooker hood 1 Chimney 2 Exhaust Pipe 1 Adaptor 1 cable tie 1 Plate I 1 Plate II 1 Screw 4mm x 40mm 4 Wall plug 8 Screw 4mm x 8mm 6 Screw 4mm x 30mm 4...

Page 6: ...e should be made prior to installation RECIRCULATION This cooker hood also supports the recirculation of air once it has passed through the filters The filtered air is then expelled through the vent h...

Page 7: ...on a suitable place once the installation height is fixed and keep it in line The fixed position of the inside chimney bracket is the place of chimney Also install the safety hole in the wall Total d...

Page 8: ...lease note the small spindles lugs at each end of each flap locate into the holes on the housing not the grooves above them 6 Hang the cooker hood on wall 7 Install the v flap and converter onto the c...

Page 9: ...e chimney bracket and fix with 2 x screws 4mmx8mm then fix the outer chimney bracket into wall with 2 x screws 4mm x 40mm pull out the exhaust pipe to outside 10 Pull up the inner chimney and fix it i...

Page 10: ...ound inside the cooker hood and all the data inside the appliance are exactly the same as the voltage and frequency in your home Then plug the power lead into the power socket or if connecting directl...

Page 11: ...e lock and pull it downward as below Put the activated carbon filter onto the end of the motor unit and turn it in anti clockwise direction Repeat the same on the other side see diagram NOTE Make sure...

Page 12: ...y pressing button Press the lamp button to reduce the hour by 1 each time After setting the hour you can start setting the minute by pressing button again on LCD flashes which represents minutes Follo...

Page 13: ...he temperature below 60 degrees Or wash by hand with warm soapy water making sure to dry thoroughly Make sure that the hood is disconnected from the mains before cleaning or maintenance Replacement gr...

Page 14: ...ibration The fan blade is damaged Switch off the unit Repair to be carried out by qualified service personnel only The fan motor is not fixed tightly Switch off the unit Repair to be carried out by qu...

Page 15: ...ncy point WBEP 145 4 W Nominal power of the lighting system WL 1 0 W Average illumination of the lighting system on the cooking surface Emiddle 41 lux Measured power consumption on standby mode PS 0 4...

Page 16: ...AM 5PM Monday to Friday www electriQ co uk Unit J6 Lowfields Business Park Lowfields Way Elland West Yorkshire HX5 9DA Recycling facilities are now available for all customers at which you can deposit...

Reviews: