TROUBLESHOOTING

 

 
NOTE:  

Any electrical repairs to this appliance must conform to your local, state and federal 
laws.Please contact the service centre if in any doubt before undertaking any of the 
above.Always disconnect the unit from the power source when opening the unit. 

 

 

Fault 

Possible Cause 

Solution 

Light on, but motor 
does not work 

Fan switch turned off 

Select a fan switch position. 

Fan switch failed 

Contact service center. 

Motor failed 

Contact service center. 

Light does not 
work, motor does 
not work 

House fuses blown 

Reset/Replace fuses. 

Power cord loose or 
disconnected 

Refit cord to power outlet. 
Switch power outlet on. 

Oil leakage 

One way valve and the outlet 
are not tightly sealed 

Take down the one way valve 
and seal with sealant. 

Leakage from the connection of 
chimney and cover 

Take chimney down and seal. 

Lights not working 

Broken/Faulty globes 

Replace globes as per this 
instruction. 

Insufficient suction 

The distance between the 
cooker hood and the gas top is 
too far 

Refit the cooker hood to the 
correct distance. 

The Cooker hood 
inclines 

The fixing screw not tight 
enough 

Tighten the hanging screw and 
make it horizontal. 

Summary of Contents for eiQ60touchslimhe

Page 1: ...OL COOKER HOOD eiQ60touchslimhe eiQ90touchslimhe Thank you for choosing electriQ Please read this user manual before using this product and keep it safe for future reference Visit our page www electri...

Page 2: ...TENTS SAFETY 3 PRODUCT OVERVIEW 5 VENTILATION 6 INSTALLATION 7 OPERATION 9 FILTER CLEANING AND REPLACEMENT 10 BULB REPLACEMENT 11 CLEANING AND MAINTENANCE 11 TROUBLESHOOTING 12 SUPPORT 12 PRODUCT FICH...

Page 3: ...cessively greasy They should be cleaned regularly see Maintenance or replaced as necessary The extraction fan must be level to avoid grease collection at one end as this could cause a potential fire r...

Page 4: ...ugh a suitable sized opening which cannot be sealed during operation A number of alternative solutions are available to ensure this If in any doubt professional advice should be sought Regulations con...

Page 5: ...5 PRODUCT OVERVIEW...

Page 6: ...dy The images only show an example of how to mount the V flap the outlet may be various according to different models and configuration To mount the V flap 1 you should 1 Mount two half parts 2 into t...

Page 7: ...means of an extraction duct enamel aluminum flexible pipe or non flammable material with an interior diameter of 150mm 1 Before installation turn the unit off and unplug it from the outlet 2 The cooke...

Page 8: ...e chimney with 2 pcs ST4 8mm screws and be sure that the inside chimney can be adjusted the height in it freely Afterwards install chimneys on the cooker hood Lay the expansion pipe to the wall outlet...

Page 9: ...for any other appliance such as warmer tube gas tube hot wind tube The angle of the bend of the expansion pipe should not be less than 120 you must direct the pipe horizontally or alternatively the pi...

Page 10: ...r cooking habit The installation procedure of activated carbon filter is as below Replacements are available from the retailer the hood was purchased from under reference eiqmidcarbon 1 The aluminum f...

Page 11: ...ut the light wire If the light wire cannot be pulled out it can be cut directly with scissors Apply the reverse procedure to install the light back ILCOS D code for this lamp is DSS 1 5 S 70 MAX WATTA...

Page 12: ...ht does not work motor does not work House fuses blown Reset Replace fuses Power cord loose or disconnected Refit cord to power outlet Switch power outlet on Oil leakage One way valve and the outlet a...

Page 13: ...AM 5PM Monday to Friday www electriQ co uk Unit J6 Lowfields Business Park Low elds Way Elland West Yorkshire HX5 9DA Recycling facilities are now available for all customers at which you can deposit...

Page 14: ...nt PBEP 264 Pa Maximum air flow Qmax 480 3 m3 h Measured electric power input at best efficiency point WBEP 61 8 W Nominal power of the lighting system WL 3 0 W Measured power of the lighting system W...

Reviews: