ElectrIQ eiQ60PBSLIMEN User Manual Download Page 12

 

 

BULB REPLACEMENT 

 

Before changing the bulb, ensure the hood is turned off and the power is disconnected before 
attempting to change the bulb.  Wait until the flitting has cooled down before commencing 
replacement. 

 

 Open the LED light plate assembly and take away the grease filter. See pic 1. 

 Find the light wire at the back of the wire  outlet. Then slightly pull the light connecting wire out, and 

dismantle the terminal of the light connecting wire. See pic 2. 

 Remove 4pcs screws on the hinge of light plate assembly, take out the light plate assembly and pull 

out the light wire. If the light wire cannot be pulled out, it can be cut directly with scissors. 

 Apply the reverse procedure to install the light back. 

 

 

 
 
 
 
 

   

 

 

 

MAINTENANCE 

Before cleaning, switch the unit off and pull out the plug, or switch off at the relevant mains switch if 
the unit has been hard-wired in. Make sure the unit has no power being fed to it. 

 
REGULAR CLEANING 

Use a soft cloth moistened with warm mildly soapy water or household cleaning detergent. Never use 
metal pads, chemicals, abrasive material or a stiff brush to clean the unit.  

 
NOTE

Do not use a steam-cleaner to clean the hood; electrical components could be damaged or 

short-circuit as a result. 

 

 

Summary of Contents for eiQ60PBSLIMEN

Page 1: ...OOD eiQ60PBSLIMEN eiQ90PBSLIMEN Thank you for choosing electriQ Please read this user manual before using this product and keep it safe for future reference Visit our page www electriQ co uk for our e...

Page 2: ...IEW 5 PARTS LIST 6 INSTALLATION 7 V FLAP INSTALLATION 7 OPTIONS FOR VENTILATION 8 INSTALLING THE UNIT 9 OPERATION 10 FILTER INFORMATION 11 BULB REPLACEMENT 12 CLEANING AND MAINTENANCE 12 TROUBLESHOOTI...

Page 3: ...rheated fat or oils might catch fire If the cooker hood is damaged do not attempt to use it If the supply cord is damaged it must be replaced by the manufacturer its service agent or a similarly quali...

Page 4: ...otential fire risk if cleaning is not carried out in accordance with the instructions Clean your appliance periodically by following the method given in the chapter MAINTENANCE If used in recirculatio...

Page 5: ...5 PRODUCT OVERVIEW...

Page 6: ...1 1 Hood Body 2 1 1 Lower decorative chimney 2 2 1 Upper decorative chimney 3 1 V flap 4 1 Exhaust pipe Not included 5 1 Charcoal filter 6 6 Screws 4 2 x 9 5 Screws 4x8 7 7 Wall Plugs 8 2 Chimney fix...

Page 7: ...dy The images only show an example of how to mount the V flap the outlet may be various according to different models and configuration To mount the V flap 1 you should 1 Mount two half parts 2 into t...

Page 8: ...eans of an extraction duct enamel aluminum flexible pipe or non flammable material with an interior diameter of 150mm 1 Before installation turn the unit off and unplug it from the outlet 2 The cooker...

Page 9: ...her side checking that the two marks are on the same horizontal line Mark a point 3 on the horizontal line C 150 mm to the vertical reference line Repeat this operation on the other side checking that...

Page 10: ...the ducting system of the hood to any existing ventilation system which is being used for any other appliance such as warmer tube gas tube hot wind tube The angle of the bend of the expansion pipe sho...

Page 11: ...hs according to your cooking habit The installation procedure of activated carbon filter is as below Replacements are available from the retailer the hood was purchased from under reference eiqmidcar9...

Page 12: ...embly take out the light plate assembly and pull out the light wire If the light wire cannot be pulled out it can be cut directly with scissors Apply the reverse procedure to install the light back MA...

Page 13: ...ht does not work motor does not work House fuses blown Reset Replace fuses Power cord loose or disconnected Refit cord to power outlet Switch power outlet on Oil leakage One way valve and the outlet a...

Page 14: ...M 5PM Monday to Friday www electriQ co uk Unit J6 Lowfields Business Park Low elds Way Elland West Yorkshire HX5 9DA Recycling facilities are now available for all customers at which you can deposit y...

Page 15: ...BEP 144 Pa Maximum air flow Qmax 342 0 m3 h Measured electric power input at best efficiency point WBEP 49 5 W Nominal power of the lighting system WL 1 5 1 W Measured power of the lighting system WL...