Maintenance

 

Cleaning 

 

Please shut off the unit and unplug from the mains before cleaning or performing any 
maintenance

 

Clean the surface 

Clean the plastic housing with a duster or a soft wet cloth.   
Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible 
damage.   

Air filter cleaning 

a)

 

Clean the air filters every 2 weeks. If the air filter is blocked with dust, the unit’s performance 
will be significantly affected.

   

b)

 

Pull out the top and bottom filters as pictured below

 

c)

 

Wash the air filters by immersing them in warm (about 40°C) water with a neutral detergent.

 

d)

 

Rinse it and then dry it thoroughly.

 

e)

 

Carefully re-install air filters   

 

 
Open from here 
 
 
 
 

 
 
 
 

End of Season Maintenance

 

1.

 

Pull out the plug from the drainage hole and empty the internal tank. You can also drain 
the water by leaning the unit. 

2.

 

Then switch the unit to low fan mode 

3.

 

Keep the unit in this mode for half day - until the conduit is dried. Doing this helps to keep 
the inside of the unit dry and prevents mold developing 

4.

 

Turn off the unit and pull out the plug. 

 

5.

 

Separate the air-exhausted pipe and store it safely.

   

6.

 

Cover the unit and keep it in a dry place. 

Summary of Contents for AIRCUBE AC9000E

Page 1: ...WITH HEAT PUMP USER MANUAL Thank you for choosing ElectrIQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electrIQ...

Page 2: ...Page 2 of 13 CONTENTS 1 SAFETY INSTRUCTIONS 3 2 FEATURES AND PARTS LIST 4 3 INSTALLATION 5 4 OPERATION AND SETTINGS 7 5 WATER DRAINAGE 8 6 MAINTENANCE 9 7 TROUBLE SHOOTING 11 8 APPENDIX 12...

Page 3: ...service other than regular cleaning or filter replacement should be performed by an authorized service representative Failure to comply could result in a voided warranty Do not use the appliance for...

Page 4: ...ne The hot air outlet is positioned high on the unit this allows for improved performance with the use of a short hose Two Speeds fan great for selecting improved performance vs quitter operation Adva...

Page 5: ...from under the unit as in the picture attached Install the exhaust hose on the unit before operating the unit CONTENTS 1 Air conditioner unit 2 Side hose mount 3 Hose and window kit Assemble the hose...

Page 6: ...made to be used with any other style of windows However the fish tail adaptor can be used with most windows doors but there will be an cold air escape making unit less efficient When using the coolin...

Page 7: ...e OFF position and the unit will stop operating FAN MODE Low Fan Speed Turn the control knob to the position the unit operates at low fan speed High Fan Speed Turn the control switch to the position t...

Page 8: ...de If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated Please make sure that the rubber cap is firmly secured on drain hose when the un...

Page 9: ...en operating the heating function the low rubber cap on drain port could be pulled out and install a permanent drain pipe in order to improve the heating effect When the water tank fills the FULL ligh...

Page 10: ...bottom filters as pictured below c Wash the air filters by immersing them in warm about 40 C water with a neutral detergent d Rinse it and then dry it thoroughly e Carefully re install air filters Ope...

Page 11: ...temperature too low or too high Windows or doors open Large amount of people or a heat source in the room Close windows and turn on another air conditioner Filter is very dirty Clean or change the air...

Page 12: ...our equipment Please contact the local council for details of your local household waste recycling centres TECHNICAL DATA AC9000E nglish V1 0230114 MODEL AIRCUBE AC9000E Capacity Cooling 2 kW Heating...

Page 13: ...1057 or complete the online form 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if...

Reviews: