1.  Purpose 

This Manual is intended to provide descriptive information of the Survivor Locator Light 
WAB-H12, information for its maintenance and overhaul, instruction concerning the proper 
mounting of the light on the life vests or life rafts to ensure continued compliance with 
prescribed minimum performance standards and pertinent operating instructions and 
limitations for the device. 

2.  Description of Device 

The Survivor Locator Light WAB-H12 is a single-use product that consists of a water-
activated battery and a light assembly, connected by an electrical wire. 

The battery consists of a cuprous chloride cathode flanked by magnesium alloy anodes in an 
injection-molded plastic case. The case contains two holes, one on the bottom and one on the 
side near the top. The holes allow water to enter the cavities between the cathode and flanking 
anodes and act as an electrolyte. 

The holes are covered with a water-soluble film, which allows automatic activation in less 
than 60 seconds when the battery is immersed in fresh water or seawater. 

The light assembly consists of a 1.5-Volt miniature incandescent lamp mounted in a plastic 
bulb holder and covered by a clear plastic lens. 

3.  Operating Instructions 

The Survivor Locator Light WAB-H12 is activated automatically within 60 seconds of 
immersion of the battery in fresh water or seawater, and the light will light automatically 

4.  Maintenance and Overhaul Information 

1.

 

Periodic overhaul is not required. Overhaul at end of life is not possible. Defective 
units (see Para. 8.3) must be returned to the manufacturer or otherwise disposed of. 

2.

 

No maintenance is required, except as noted in paragraph. 8.3. 

5.  Instructions for Mounting on Life Vests 

1.

 

The recommended method for mounting the WAB-H12 on life vests is: 

a)

 

Attach light assembly to vest at the fabric attachment point ring provided on vest, by 
first inserting lens through fabric attachment point ring and then pushing upper ring 
on plastic bulb holder through fabric attachment ring. 

b)

 

Attach battery firmly to vest harness by wrapping around several times with adhesive 
strip or other attachment means recommended by vest manufacturer. 

Summary of Contents for WAB-H12

Page 1: ...any time CONTENT 1 Purpose 2 Description of Device 3 Operating Instructions 4 Maintenance and Overhaul Information 5 Instructions for Mounting on Life Vests 6 Instructions for Mounting on Life Rafts 7 Storage Instructions 8 Limitations of the Device The conditions and test required for TSO approval of this article are minimum performance standards It is the responsibility of those desiring to inst...

Page 2: ...t as an electrolyte The holes are covered with a water soluble film which allows automatic activation in less than 60 seconds when the battery is immersed in fresh water or seawater The light assembly consists of a 1 5 Volt miniature incandescent lamp mounted in a plastic bulb holder and covered by a clear plastic lens 3 Operating Instructions The Survivor Locator Light WAB H12 is activated automa...

Page 3: ...ng on Life Rafts 1 The recommended method for mounting the WAB H12 on life rafts is a Insert light assembly in raft light holder b Insert battery in battery holder opposite the light holder 2 Other methods of mounting the WAB H12 on life vests may be used by the life vest manufacturer but the method should be in such a way that it will not damage the battery The battery case should not be exposed ...

Page 4: ...onsibility in the event of any failure to follow these installation instructions exactly 8 Limitations of the Device 1 The single use Survivor Locator Light WAB H12 is designed to provide light intensity of at least one 1 0 candlepower cd in all of the directions required by TSO C85 for a minimum of twelve 12 hours after activation 2 Once activated by immersion in water or any other conductive liq...